The controller allows setting up to 4 comfort periods (system on) for each single zone with daily start and end time,
and set temperature. In the times not programmed, the set back temperature will be maintained. The controller will
regulate the temperature in each single zone so as to maintain the set temperature by acting on the boiler and
valves. During initial configuration, the controller automatically assigns standard parameters to each zone (see the
diagram below).
Starting from the main menu select:
–>
–>
MODIFY
Select the zone to be modified, for example LIVING ROOM. The following page will appear:
Pressing the confirmation button in correspondence to the day of the week selected, you can modify the following
parameters:
ADD
Allows adding a time period with start, end time and setpoint (regulation temperature)
A maximum of four time periods can be set. Follow the on-screen instructions.
MODIFY
Allows modifying the values relating to an existing time period with start, end time and
setpoint (regulation temperature). Follow the on-screen instructions.
DELETE
Allows to delete a time period. Follow the on-screen instructions.
COPY
Allows copying and using the settings of any one day of the week for all the other days.
Follow the on-screen instructions. This function is very useful if you want to have the same
program for all the days of the week. Repeatedly press the confirmation button.
ZONE PROGRAM MENU
(to program the system operating times)
START
07:30
12:00
18:00
OTHER TIMES
END
08:30
13:30
22:30
SETP
22.0°C
22.0°C
22.0°C
16.0°C
LIVING ROOM
ZONE PROGRAM
THU
24/04/14
14:48
MONDAY
SELECT A DAY
Start time
End time
Temperature set for the
comfort period
Temperature set for the
set back period
(outside the set times)
MODIFY
MENU
ZONE PROGRAM
MODIFY
MODIFY
ADD
DELETE
COPY
18