• LCD display

Allows  viewing  of  heating  and  domestic  hot  water  set  point

temperatures and the error codes.

Stand-by:

The following alternate every 5 seconds on the display:

The set point temperature is shown while the 

symbol flashes:

(the  return  temperature  is  displayed  if

temperature  regulation  with  compensated  set

point regulation is active, see page 9)

The set point temperature is shown while the 
symbol flashes:

Domestic cycle ON:

Heating temperature set point

(the  return  temperature  is  displayed  if

temperature  regulation  with  compensated  set

point regulation is active, see page 9)

60

 

 

 

60

 

 

 

48

 

 

 

Domestic hot water temperature set point

48

 

 

 

• Trimmers for set point settings

These allow setting of the temperature set point for the heating and

domestic  water  cycle  (on  low  and  medium  temperature  models)

and view the associated set value on the display.

• RESET key

User interface

The  user  interface,  built  into  the  PCB,  consists  of  the  following

devices:  

• LED indicator

The various functions and faults are signalled by either flashing or

steady illumination of the LEDs.

ON 

Electric supply 230 V (ac)

DHW  - 

Domestic cycle

CH 

Heating cycle

FAULT - 

Fault detected

Domestic cycle

Heating cycle 

Operating principle

All  heating  and  domestic  hot  water  functions  offered  by 

SATK20 series HIUs are controlled by a digital controller. 

The controller is factory set with different parameters and settings

depending on the model (Table 1).

There  are  a  number  of  specific  DIP  SWITCHES  on  the  controller

circuit  board;  the  way  these  are  configured  will  determine  the

settings of the various models and the optional functions enabled.

Electronic regulator

1

2

3

4

5

6

This allows restoration of normal function after the

safety  thermostat  has  been  triggered  and

activation/deactivation  of  the  floor  slab  heating

function.

CODE

SWITCH SETTING

SET POINT

6

5

4

3

2

1

HEATING

DHW

SATK20103HE 

LOW temperature

25 – 45°C

42 – 60°C

SATK20203HE 

MEDIUM temperature

45 – 75°C

42 – 60°C

SATK20303 / 20403HE / 20305

HIGH temperature

-

42 – 60°C

Table 1 – factory default settings

Factory set (do not change)   

May be changed to activate optional functions
Switch 1: modulating temperature regulation with compensated set point 
Switch 5: domestic hot water pre-heating function

OFF

ON

OFF

ON

see page

13

Heating cycle ON:

Summary of Contents for SATK20 Series

Page 1: ...ms Product range SATK20103HE Direct wall mounted HIU for LOW temperature heating instantaneous domestic hot water production power capacity 40 kW SATK20203HE Direct wall mounted HIU for MEDIUM tempera...

Page 2: ...high intensity electromagnetic fields This device cannot be used in areas at risk of explosion or fire 3 The device must be connected to an independent bipolar switch If work has to be done on the de...

Page 3: ...ell cover EPP Heat exchanger brazed stainless steel SATK20305 technical specifications Medium water Maximum percentage of glycol 30 Maximum medium temperature 85 C Maximum working pressure primary cir...

Page 4: ...ontact a qualified technician to request a thorough check of the electrical system Electrical safety of the appliance is only achieved when it is correctly connected to an effective earthing system ma...

Page 5: ...centralised system It is advisable to install manual shut off valves not supplied also on the bottom connections to the apartment circuits Before installation it is recommended to carry out accurate...

Page 6: ...r steady illumination of the LEDs ON Electric supply 230 V ac DHW Domestic cycle CH Heating cycle FAULT Fault detected Domestic cycle Heating cycle Operating principle All heating and domestic hot wat...

Page 7: ...lty safety valve is working properly again Thermal safety valve fault SATK20103HE LOW temperature Error code 76 76 Removing a fault Normal operating conditions are restored automatically once the faul...

Page 8: ...ner heat meter flow probe pocket 18 Primary circuit shut off valves SATK20103HE LOW temperature heat interface unit with high efficiency pump Functional characteristics Heating range 45 75 C Set point...

Page 9: ...a temperature of 45 C Once the maximum set point has been reached the function is executed following the same procedures in reverse from the maximum set point to the minimum set point This function h...

Page 10: ...ctory settings 1 2 3 4 5 6 4 ON Functional characteristics Maximum heating temp 85 C ON OFF regulation DHW production range 42 60 C Optional functions Domestic cycle DHW pre heating function 1 2 3 4 5...

Page 11: ...circulate at the temperature supplied by the central heating system ON OFF regulation The valve is closed on completion of the heating cycle The active heating cycle is signalled by lighting of the ye...

Page 12: ...inserted Replacing the valve actuator Disconnect the actuator cable lightly pressing the tab on the connector and extracting it see page 13 ref 4 8 Extract the fixing clip D and then the actuator Posi...

Page 13: ...pulito Room thermostat Volt free connection This connection may not be available To be wired during installation Room thermostat not supplied potential free line MAX 30 m 6 ON Dip switch 6 configurati...

Page 14: ...d heat exchanger partly clogged call qualified personnel to have it serviced modulating valve actuator faulty call qualified personnel to have it replaced valve obturator blocked in intermediate posit...

Page 15: ...ced primary circuit flow rate insufficient contact person in charge of system centralised system not working contact person in charge of system CH LED off chrono thermostat time setting incorrect chec...

Page 16: ...ve result Are the connections compliant with specifications and made in accordance with best practices 13 all Are the shut off valves open 14 all Has the visual inspection of the hydraulic connections...

Reviews: