INSTALLATION

ALS

600T-AD

2019.12.5 Rev 2

Mounting Fixture

2. 

Mark location where mounting clips will be installed. Quantity of mounting clips = quantity

       of f1. Use a mounting clip at the joint between two fixtures (for dry location only).

5. 

Screw mounting clips to surface, then snap fixture into mounting clips. Install set screws if

       necessary. Set screws required for downward and outward facing applications.

Set Screw

4. 

If applicable, connect disconnects between fixtures. Push and twist cap to lock connector.

      

Note:

 Shrink tube required for wet location installations.

4’

Mounting Clip

2”

2”

2’

2”

2”

3’

2”

2”

2”

2”

1’

Shrink Tube

Apply Heat

3. 

Lay mounting clips and pre-drill using proper drill bit for surface and screw size.

      

Recommendation:

 8/32 x 1” screw.

      

Note:

 Allow 0.25” clearance for lateral expansion of assembled mounting clips.

                 Only install mounting clips on flat, even surfaces.

6. 

Perform continuity test steps on page 10 before connecting fixture to power source.

1. 

Measure area where luminaire will be installed. Use a chalk line to ensure a straight installation.

Summary of Contents for alumLEDs ALS600T-AD-AA-SM Series

Page 1: ...f LED colors and whites Available in 3 Watts up to 24 Watts Per Foot product is shipped in 1 2 3 and 4 luminaires Available for outdoor rated installations INSTALLATION RECOMMENDATIONS AlumLEDs can be...

Page 2: ...nsult factory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion...

Page 3: ...e or inadvertently in the wiring the current on the control bus will be less than 1 5mA As can be determined from the two items simple two level operation of the drivers can be achieved by proper usag...

Page 4: ...ew size Recommendation 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips...

Page 5: ...imum of two mounting arms per fixture Mount arms 6 from center of mounting plate to end of fixture Refer to spacing diagrams for details 3 Mark location where mounting arms will be installed Screw arm...

Page 6: ...ing is accurate according to the spacing diagram Set Screw 5 Loosen set screw until the mounting bracket can move freely Turn the mounting bracket until desired angle is achieved then mate the locking...

Page 7: ...make changes or withdraw specifications without prior notice Page 7 of 11 INSTALLATION ALS600T AD 2019 12 5 Rev 2 Accessories ALS600T AD LVR 1 Place louvers onto top of extrusion ensuring internal opt...

Page 8: ...n 1 Slightly unscrew Pivot Lock Knobs on both ends of fixture until Pivot Lock Bar and Upper Extrusion move freely Do not remove Pivot Lock Knob 2 Adjust as needed Use Angle Finder Markings on end cap...

Page 9: ...en snap fixture into mounting clips Install set screws if necessary Set screws required for downward and outward facing applications Set Screw 4 If applicable connect disconnects between fixtures Push...

Page 10: ...obe to a wire and the black probe to each other wire Repeat for each wire If a conductive path is formed between any of the wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify...

Page 11: ...carbonate 6 18AWG stranded 105 C stripped 3 8 tinned 60Hz PRODUCT FEATURES The Surge Series are 3 leaded devices that protect Line Ground Line Neutral and Neutral Ground in accordance with IEEE ANSI C...

Reviews: