empty, the ACU is not connected properly. If there are more entries in the list, the
configuration program has found other devices in this network segment which use the same
technology.
6. Now open with a right-click the sub-menu IP configuration to open the IP configuration
window of the program. In this form the ACU's MAC address is shown on top, below you find
the fields to configure the new IP address and network mask. If the ACU later shall be
operated through a router, enter the address of the router on the gateway field, otherwise
leave this field blank. Be sure, that the 'DHCP' mark is unchecked, the other values have to
be set as shown on the picture. Finally click to the 'Yes' button to set the new parameters at
the ACU.
Now the IP configuration of the ACU is completed. You may finally want to test if the ACU is
reachable now. Start your web browser and type the ACU's IP address into the URL field of the
browser. The ACU should reply with it's main page, provided that the ACU and your computer are
configured for the same subnet.
Connect the limit switches to the sat-nms ACU-ODM as described in chapter
4.2.2 Pin description
.
1. Apply 24V DC to the ACU-ODM. Take care, that the motor drivers are not powered up yet.
The sat-nms ACU-ODM should be reachable via Ethernet now.
2. Check the function and correlation of all limit-switches manually. On the sat-nms ACU-ODM
main-webpage a limit fault is shown as soon it occurs. On the test-page every single limit
switch is displayed. For more detailed informations see chapter
5 Operation
Connect the angle detectors to the sat-nms ACU-ODM as described in chapter
4.2.2 Pin
description
.
1. Configure the desired type of detector on the setup-page.
2. Set the soft-limits to the expected values (at first it is ok if you do this approximately, later on
you need to type in here the exact values).
3. Check the rotational direction of the resolvers. If possible, do this by turning the resolver axis
directly, otherwise you have to move the antenna by hand. Maybe you have to invert the
rotational direction on the setup page.
4. Set the offset of the angle detectors to the desired values by using the calc function