If you need more detailed information, please refer to chapter
5.6 Setup
.
Before you connect the motors to the sat-nms ACU-ODM, take care that the motor drivers are not
powered up yet.
1. Connect the motor drivers to the sat-nms ACU-ODM as described in chapter
4.2.2
.
2. Press the STOP button on the sat-nms ACU-ODMs website. By this you can be sure that no
motor movement will occur by switching on the motor drivers.
3. Turn on power supply for the motor drivers, they have to run now.
4. If you use frequency inverters as motor drivers, set now the motor parameters to the
frequency inverters as written in their documentation.
5. Check the motor rotating directions, if necessary change it by interchanging 2 phase-wires
of the motor cable (3phase motor) or inter and - cable (DC motor).
6. Drive the antenna in every direction (AZ, EL and if available POL) until the limit switches stop
the motor movement to ensure that the limit switches work well. ATTENTION! While doing this
test it is absolutely necessary to be very mindful to check, if nothing collides!
7. Set the soft-limits to the desired values (e.g. 1° before the hardware limit switch is activated)
Now, the setup of all interfaces to the antenna is done. By this everything is prepared to configure
the ACU to the desired operation mode, to save targets and finally to set the sat-nms ACU-ODM
into service.
In chapter
5 Operation
you find a detailed description of the pointing and tracking parameters.
To use the function pointing by stating an orbit position you have to configure the 'Location'
parameters on the setup page to the geodetic location of your antenna. Take care to type in
position with enough accuracy (0.001°). For further informations, please refer to chapter
5.6
Setup
for location parameters and
5.3 Target Memory
for using this pointing function.
The last step that is recommended to be done is the backup of ACU settings. By this way an easy
replacement of the ACU-ODM could be performed. The following step-by step description shows
how to do this.
1. Open the chiptool
2. Right click to the desired unit. A drop-down list will open, choose FTP
3. A small window like shown on the following picture will be opened. Please double-check the
(C) 2022, SatService GmbH
www.satnms.com
ACU-ODM-UM-2209 Page 24/73