9
PRESSURE TESTING AND HOOKUPS - cont’d
LP GAS HOOK-UP
»
Never connect an unregulated gas line to the grill. LP unit grills come equipped with a high capacity hose/regulator
assembly (Type 1 QCC1) for connection to a standard 20LB LP cylinder (type 1). The LP tank is NOT included. Place the
tank into the slide out tank holder and connect as shown below. If the unit is to be hard-piped to an external LP supply, contact
your local gas utility company for instructions in installing this appliance.
»
Operating pressure: 10” WC
»
To avoid heat degradation (loss of heat) keep the supply as short as possible
LP TANKS
»
A dented or rusty LP tank may be hazardous and should be checked by your LP cylinder supplier. Never use a cylinder with a
damaged valve.
»
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas Cylinders of the US de-
partment of Transportation (DOT).
»
The cylinder must be provided with a shut-off valve terminating in an LP gas supply cylinder valve outlet specified, as
applicable, for connection type QCC-1 in the standard for compressed gas cylinder valve outlet and inlet connection
ANSI/CGA-V-1.
NOTE: The LP Tank is NOT INCLUDED with the grill and must be purchased separately from your local LP cylinder supplier.