12
LEAK TESTING
Note:
When an LP unit is being directly connected to an LP house system, you must follow the natural gas hook up guide-
lines. The installer must provide the proper gas regulator to reduce the gas flow to 11” W.C.
Note:
The Grill does not come with the LP Regulator/Hose assembly installed. The Regulator/Hose assembly should be
tested by the installer for any leaks.
WARNING
:
Check the hose, regulator and connectors for damage before each use.
Look for cracks, abrasions, brittleness, holes, dents and nicks.
Do not attempt to remove, repair, or replace the Regulator/Hose assembly by yourself. It must be done by a qualified
licensed technician only
QUICK
DISCONNECT
LEAK TEST
POINT
LEAK TEST
POINT
LEAK TEST
POINT
REGULATOR
View of properly connected LP hose to a
20# LP tank
See below for leak test points.
Note:
Before each use, check LP hose for any
signs of stress or cracks and replace if there
are signs of aging or cracking