pre-operatIon checklISt

package contents 

model:  20040dcadc

package contents:

*    Air Filters (4)
*    3’ Tubing (for auto drain valve)
*    4’ Tubing (for the air dryer)
* Owner's Manual

assembly:

Install the air filters.

1. Screw the four air filters into the 4 ports located on 

the top left side of the motor heads.

Inspect for damage

before using the air compressor, make sure the air tank is not

damaged, inspect all parts for damage, and check that all pipes

are firmly connected.
do not use the air compressor if any damage is found. If

damaged, have an authorized service center inspect and test the

air compressor to ensure that is working properly.

Save packaging

Save all outside packaging in case you ever need to return the

product for service or repair.

compressor location

use on flat Surface

For proper operation, the air compressor must be placed on a flat

surface with an incline no greater than 15 degrees.

maintain a clear area

It is very important that the air compressor is positioned so that

there is adequate airflow around the machine. There must be at

least 2 feet of obstacle-free space surrounding and above the air

compressor.

use in areas with clean air

For proper operation and to maximize the longevity of the air

compressor, it is very important that the air drawn into the air

compressor is clean. The air compressor should not be used in

areas where dust or particulates are in the air. This will damage

the motor and impair proper operation. 

Important:

Always use the air filter, properly installed.

Use caution to minimize risk of fire or explosion.

It is normal for the air compressor motor and 
pressure switch to produce sparks while operating. If 
sparks come in contact with vapors from gasoline or 
solvents, they may ignite and cause a fire or 
explosion.

Abrasive tools such as grinders, drills and other 
tools are capable of making sparks that can ignite 
flammable materials.

Always operate the air compressor a safe distance 
away from flammable items. Use in well-ventilated 
areas.

Never exceed the maximum rated pressure.

FIRE

WARNING

EXPLOSION

Dust or dust-like particulates caused by 
power-sanding, sawing, grinding, drilling or any 
other construction-like activities can contain 
contaminants that are harmful to breathe.

Always use your air compressor in a well-ventilated 
and clean area.

Never breathe the air that comes directly out of the 
air compressor or air hose. This air is not suitable for 
breathing.

Always wear approved safety equipment. When 
performing dust-creating activities, securely wear 
properly-fit face masks or respirators.

If you feel ill from breathing while operating your air 
compressor, stop and seek medical attention 
immediately.

WARNING

RISK TO BREATHING

AiR COMPReSSOR

Summary of Contents for 20040DCADC

Page 1: ...LTRA dRy OiL FRee AiR COMPReSSOR OwneR S MAnUAL CALiFORniA AiR TOOLS 20040dCAdC 4 0 HP 20 gALLOn 220 vOLTS 60 HeRTz AiR dRying SySTeM AUTOMATiC dRAin vALve WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Page 2: ...enance _________________________________11 draining the air tank air dryer _________________11 changing the air filter__________________________11 testing for leaks ______________________________11 cleaning _____________________________________11 Storage ______________________________________11 trouBleShootIng ____________________________12 SpecIfIcatIonS________________________________13 electric...

Page 3: ...he grounding plug is able to result in a risk of electric shock When repair or replacement of the in a risk of electric shock When repair or replacement of the cord or plug is required do not connect the grounding wire cord or plug is required do not connect the grounding wire to either flat terminal The wire with insulation having an to either flat terminal The wire with insulation having an oute...

Page 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Page 5: ...chments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If spar...

Page 6: ...de important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PROduCT LAbeL a B c d e f g h AiR COMPReSSOR ...

Page 7: ...7 Customer Support 1 866 409 4581 AiR COMPReSSOR ...

Page 8: ... very important that the air drawn into the air compressor is clean The air compressor should not be used in areas where dust or particulates are in the air This will damage the motor and impair proper operation Important Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks whi...

Page 9: ...O NOT touch air compressor or cords if hands or feet are wet wet Ensure that all cords are free of damage before connecting Ensure that all cords are free of damage before connecting to the power supply to the power supply Ensure that you have a sufficient electrical supply for Ensure that you have a sufficient electrical supply for supporting the requirements of the motor supporting the requireme...

Page 10: ...es because they can cause severe burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects ca...

Page 11: ...onnections are tight do not overtighten A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the area suspected of leaking If the soap bubbles replace the broken part cleaning Clean items with a soft brush or wipe with a moistened cloth using a biodegradable solvent do not use flammable liquids such ...

Page 12: ...rt The motor does not start and makes a humming noise Capacitor is burned out Replace starter capacitor The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat Allow the motor to cool down Press the Reset button to resta...

Page 13: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Page 14: ...fic legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties that...

Page 15: ...e improperly wired or failure to have a certified licensed electrician install the air compressor 11 Acts of god The application of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the enclosed registration form or complete on line at www californiaairtool...

Page 16: ...______________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price _______________________________________...

Reviews: