background image

10

Customer Support: 1-866-409-4581

AIR COMPRESSOR

electrical power

electrical power requirements

before using the air compressor, refer to the serial label for voltage

and amperage requirements. Make sure you have a sufficient

electrical supply for supporting the motor's requirements. 
use a dedicated 15 amp circuit for the best results.
Low voltage and/or an overload circuit can cause the motor's

overload protection system circuit breaker to trip.

electrical extension cords

Inspect all electrical extension cords to ensure that they are free of

damage.
When using an extension cord, use a heavy-duty cord that is no

more than 25 feet long and at least 14 gauge.use only a 3-wire

extension cord that has a 3-blade grounding plug.  

OPeRATINg The AIR

COMPReSSOR

Save this manual for future reference.

Introduction

This air compressor features a compact structure, stable

performance, a high airflow rate, easy operation and maintenance.

because the air compressor produces no oil in the airflow, it can be

used as an independent air supply machine for situations in which

oil in the airflow is an issue. The motor directly drives the pistons

and is able to function without lubrication for a long period of  time.

assembly

1.

Connect your air hose or air fitting to the 3/8” port located on the

regulator.

2.

Make sure that the pressure switch is in the OFF position.

3.

ensure that the power supply you are going to use is operating

normally. use a dedicated 15 amp outlet.

4.

Insert the power supply cord into the power supply socket.

Summary of Contents for 30020CAD

Page 1: ... OIL FREE AIR COMPRESSOR OwnER S MAnUAL CALIFORnIA AIR TOOLS 30020CAD 2 0 HP 6 40 CFM 40 PSI 5 30 CFM 90 PSI 30 0 gALLOn STEEL TAnk AUTOMATIC DRAIn vALvE WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Page 2: ..._________________12 draining the air tank ___________________________12 changing the air filter__________________________12 testing for Leaks ______________________________12 pressure Switch _______________________________12 cleaning _____________________________________12 Storage______________________________________12 troubLeShootIng ____________________________13 SpecIfIcatIonS_________________...

Page 3: ...OOLS COM please provide the information below Model number and Serial number and specifications shown on the Model number Serial number plate Part number or numbers shown in the parts list section of the owner s manual for your air compressor model A brief description of the trouble with the air compressor do not return your air compressor for service or parts to the store dealer where purchased I...

Page 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Page 5: ...chments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If spar...

Page 6: ...se labels provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PROduCT LAbeL a b c d e f g h ...

Page 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Page 8: ...p front side of motor head looking from the front to the back of the air compressor Screw the air filters into the motor head ports 1 Slide bolt 73 through Wheel 72 Washer 74 and support hole located on the back bottom leg of the air compressor 2 Attach Washer 74 and Nut 75 to bolt 73 and firmly tighten 3 Repeat these steps on the other support 4 Slide bolt 78 through Washer 79 Cushion Foot 80 and...

Page 9: ...t or particulates are in the air This will damage the motor and impair proper operation Important Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion A...

Page 10: ...auge use only a 3 wire extension cord that has a 3 blade grounding plug OPeRATINg The AIR COMPReSSOR Save this manual for future reference Introduction This air compressor features a compact structure stable performance a high airflow rate easy operation and maintenance because the air compressor produces no oil in the airflow it can be used as an independent air supply machine for situations in w...

Page 11: ... surfaces because they can cause severe burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying obj...

Page 12: ...emove the air filter element 2 To clean the element blow off or brush off the dirt and dust 3 If clogged replace with a new air filter testing for Leaks Make sure all connections are tight do not overtightly A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the area suspected of leaking If the soa...

Page 13: ...windings are burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Contact Customer Support The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressor specifications An extension cord that is too thin or too long can cause a voltage drop use heavy duty extension cor...

Page 14: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Page 15: ... legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties that ma...

Page 16: ...ion of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the enclosed registration form or register on line at www californiaairtools com Click on the Customer Service Tab and the Product Registration Tab how to Videos California Air Tools provides hOW TO V...

Page 17: ...ormation date of Purchase ____________________________________________________________ MM dd yeuky Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price ______...

Reviews: