background image

12

Customer Support: 1-866-409-4581

AIR COMPRESSOR

MAINTeNANCe

draining the air tank

The frequency at which you should drain the air tank depends on

the environmental conditions and the amount of operating time

logged. The average draining frequency is every 2 to 3 days.

1.

Place the air compressor above a container capable of holding

water. 

2.

With compressed air in the air tank, slowly turn the drain valve

knob to the forward (open) or straight position.

The water in the air tank will drain out. 

3.

After all of the accumulated water has drained out, turn the

drain valve knob to the closed or left position in order to avoid

leakage.

4. 

draining the air tank protects parts from rust and corrosion.

.

cleaning or changing the air filter

The air filter is designed to reduce noise and  help prevent

particulates in the air from entering and damaging the air

compressor.
After being used for a period of time, the air filter will become

clogged. This will reduce the air intake capabilities of the air

compressor, reducing performance. Therefore, the air filter must

be cleaned or replaced regularly.

1.

Open the lid on the air filter, then remove the air filter element.

2.

To clean the element blow off or brush off the dirt and dust.

3.

If clogged, replace with a new air filter.

testing for Leaks

Make sure all connections are tight. do not overtighten.
A small leak in any hose or pipe connection will reduce the air

compressor's performance.
To test for small leaks, spray a small amount of soapy water on

the area suspected of leaking. If the soap bubbles, replace the

broken part.

cleaning

Clean items with a soft brush, or wipe with a moistened cloth

using a biodegradable solvent.
do not use flammable liquids such as gasoline or alcohol. Always

keep parts clean from dirt and dust for better performance.

pressure Switch

The pressure switch is factory pre-set to shut off at between
120 - 125  PSI and to re-start at between 90 -95 PSI

STORAGe

before storing for a prolonged period of time:

1.

Turn off the power supply.

2.

disconnect the power cord from the power supply and wrap

the power cord around the air compressor handle to reduce

the risk of damage.

3.

Pull the relief valve and release all the pressure from the air

tank.

4.

Clean the air compressor to remove all dirt and dust.

5.

Cover the air compressor with a cover to protect the unit from

dust and moisture.

6.

do not stack or store any items on top of or around the air

compressor. damage could occur.

Summary of Contents for 4620AC

Page 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OwnER S MAnUAL CALIFORnIA AIR TOOLS 4620AC 2 0 HP 6 40 CFM 40 PSI 5 30 CFM 90 PSI 4 6 gALLOn ALUMInUM TAnk WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Page 2: ..._________________12 draining the air tank ___________________________12 changing the air filter__________________________12 testing for Leaks ______________________________12 pressure Switch _______________________________12 cleaning _____________________________________12 Storage______________________________________12 troubLeShootIng ____________________________13 SpecIfIcatIonS_________________...

Page 3: ...OOLS COM please provide the information below Model number and Serial number and specifications shown on the Model number Serial number plate Part number or numbers shown in the parts list section of the owner s manual for your air compressor model A brief description of the trouble with the air compressor do not return your air compressor for service or parts to the store dealer where purchased I...

Page 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Page 5: ...eme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion Abrasive tools such as grinders drills and oth...

Page 6: ...se labels provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PROduCT LAbeL a b c d e f g h ...

Page 7: ...ton Ring 29 Holding Screw 49 Air Filter 69 Cushion Foot 10 Plate Pinch 30 Cheese Head Screw 50 Support II 70 Washer 11 Pressure Plate Screw 31 Crank Case 51 1 4 Quick Connect 71 bolt 12 Cylinder 32 Leading out Line Guard Circle 52 electromagnetism 72 bolt 13 Cylinder Obturating Ring 33 Motor Screw 53 Connecting Cord 73 Capacitor 14 Cylinder Head Obturating Ring 34 Spring Washer 54 Check Valve 74 C...

Page 8: ...assembly model 4620ac package contents Air Compressor Owner s Manual Air Filters 2 assembly Install the air filters 1 Attach the air filters to the back top right and left side of motor head looking from the front to the back of the air compressor Screw the air filters into motor head ports ...

Page 9: ...t or particulates are in the air This will damage the motor and impair proper operation Important Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion A...

Page 10: ...ding plug OPeRATING THe AIR COMPReSSOR Save this manual for future reference Introduction This air compressor features a compact structure stable performance a high airflow rate easy operation and maintenance because the air compressor produces no oil in the airflow it can be used as an independent air supply machine for situations in which oil in the airflow is an issue The motor directly drives ...

Page 11: ... cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered ...

Page 12: ...ter then remove the air filter element 2 To clean the element blow off or brush off the dirt and dust 3 If clogged replace with a new air filter testing for Leaks Make sure all connections are tight do not overtighten A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the area suspected of leaking ...

Page 13: ...windings are burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Contact Customer Support The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressor specifications An extension cord that is too thin or too long can cause a voltage drop use heavy duty extension cor...

Page 14: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Page 15: ...fic legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties that...

Page 16: ... by California Air Tools Inc 9 Acts of God The application of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the enclosed registration form or register on line how to Videos California Air Tools provides HOW TO VIdeOS on our website WWW CALIFORNIAAIRTOOL...

Page 17: ...ation date of Purchase _____________________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price _________...

Reviews: