background image

11

Customer Support: 1-866-409-4581

AIR COMPRESSOR

MAINTENANCE 

PLEASE READ  

 

Important Maintenance Required 

 

Refer to the separate Instruction Manual 
and Maintenance Instructions for the 
Scroll Pump

 

 

Replacement parts include, intake filter, v-belts, check valve o-ring, 
tips seal and grease. 

 

Ambient Temperature                      Maintenance Intervals in Hours 

Less than 84 F                                               10,000 

85 - 94 F                                                          7,000 

95 - 104 F                                                        4,900

 

 
 
 
 

Draining the Air Tank

 

The frequency at which you should drain the air tank depends on 

the environmental conditions and the amount of operating time 

logged. The average draining frequency is every 1 to 2 days. 

 

1. Place the air compressor above a container capable of holding 

    water. 

2. With compressed air in the air tank, slowly turn the drain valve 

     knob to the forward (open) or straight position. 

     The water in the air tank will drain out. 

3. After all of the accumulated water has drained out, turn the 

   drain valve knob to the closed or left position in order to avoid 

   leakage 

4

Empty the waste container of water regularly. 

5.  Highly recommended to manually drain the air tank 

regularly (Daily) from the ball drain valve to remove excess 
water.

 

6. 

Draining the air tank protects parts from rust and corrosion. 

 

 

Changing the Air Filter 

The air filter is designed to reduce noise and help prevent 
particulates in the air from entering and damaging the air 
compressor. 

After being used for a period of time, the air filter will become 
clogged. This will reduce the air intake capabilities of the air 
compressor, reducing performance. Therefore, the air filter must be 
replaced regularly. 

1.

 Open the lid of the air filter and remove the old air filter element. 

2.

 Replace with a new air filter element and close the lid. 

 

Testing for Leaks 

Make sure all connections are tight. Do not overtighten. 

A small leak in any hose or pipe connection will reduce the air 
compressor's performance. 

To test for small leaks, spray a small amount of soapy water on the 
area suspected of leaking. If the soap bubbles, replace the broken 
part. 

 

Cleaning 

Clean items with a soft brush, or wipe with a moistened cloth using 
a biodegradable solvent. 

Do not use flammable liquids such as gasoline or alcohol. Always 
keep parts clean from dirt and dust for better performance 

 

STORAGE

 

Before storing for a prolonged period of time: 

1.

 Turn off the power supply. 

2.

 Disconnect the power cord from the power supply. 

3.

 Release all of the pressure and moisture from the air tank 

through the manual drain valve. 

4.

 Clean the air compressor to remove all dirt and dust. 

5.

 Cover the air compressor with a cover to protect the unit from 

dust and moisture. 

6.

 Do not stack or store any items on top of or around the air 

compressor. Damage could occur.

Summary of Contents for 60050SCR

Page 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OWNER S MANUAL CALIFORNIA AIR TOOLS 60050SCR 5 0 HP 60 GALLON 220 VOLTS 60 HERTZ WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Page 2: ...________________10 MAINTENANCE _________________________________11 Draining the Air Tank ___________________________11 Changing the Air Filter__________________________11 Testing for Leaks ______________________________11 Cleaning _____________________________________11 STORAGE ______________________________________11 TROUBLESHOOTING ____________________________12 SPECIFICATIONS___________________...

Page 3: ...he grounding plug is able to result in a risk of electric shock When repair or replacement of the in a risk of electric shock When repair or replacement of the cord or plug is required do not connect the grounding wire cord or plug is required do not connect the grounding wire to either flat terminal The wire with insulation having an to either flat terminal The wire with insulation having an oute...

Page 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Page 5: ...chments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If spar...

Page 6: ...de important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PRODUCT LABEL A B C D E F G H AIR COMPRESSOR ...

Page 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Page 8: ...nd impair proper operation Always use the air filter properly installed Ventilation When using the air compressor in an enclosed room install a fan for ventilation BTU British Thermal Unit 12800 Ambient Temperature Use at ambient temperatures of 36 F to 104 F Using at less than 36 F will cause unit failure or freezing Use caution to minimize risk of fire or explosion It is normal for the air compr...

Page 9: ...ore connecting to the power supply to the power supply Ensure that you have a sufficient electrical supply for Ensure that you have a sufficient electrical supply for supporting the requirements of the motor supporting the requirements of the motor Improper installation of the grounding plug is able to result Improper installation of the grounding plug is able to result in a risk of electric shock...

Page 10: ...n cause severe burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to ...

Page 11: ...gned to reduce noise and help prevent particulates in the air from entering and damaging the air compressor After being used for a period of time the air filter will become clogged This will reduce the air intake capabilities of the air compressor reducing performance Therefore the air filter must be replaced regularly 1 Open the lid of the air filter and remove the old air filter element 2 Replac...

Page 12: ...re burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Replace capacitor The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat Allow the motor to cool down Ens...

Page 13: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Page 14: ...This warranty gives you specific legal rights and you may also have other rights which may vary from state to state Disclaimer of Other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any ...

Page 15: ...ed by California Air Tools Inc 9 Repairs without California Air Tools prior written approval 10 Incorrect voltage improperly wired or failure to have a certified licensed electrician install the air compressor 11 Acts of God The application of these exclusions will be determined at the sole discretion of California Air Tools Inc Maintenance Trouble Shooting WWW CALIFORNIAAIRTOOLS COM Go to the Mai...