background image

5

Customer Support: 1-866-409-4581

AIR COMPRESSOR

Improper care could lead to the air tank bursting or 
exploding.

Drain air tank daily or after each use to prevent 
moisture buildup in the air tank.

Rust can weaken the air tank and cause leaks or 
bursting. If rust is detected, replace tank 
immediately. Do not try to repair the air tank by 
welding, drilling or modifying it in any other way. 
These modifications can weaken the air tank and 
cause a hazardous condition.

If air tank develops a leak, replace the air tank 
immediately. Never repair, weld or make 
modifications to the air tank or its attachments.

Never make adjustments to the factory-set 
pressures.

Never exceed manufacturer's maximum-allowable 
pressure rating attachments.

Because of extreme heat, do not use plastic pipe or 
lead tin solder joints for a discharge line.

WARNING

EXPLOSION

Use caution to minimize risk of fire or explosion.

It is normal for the air compressor motor and 
pressure switch to produce sparks while operating. If 
sparks come in contact with vapors from gasoline or 
solvents, they may ignite and cause a fire or 
explosion.

Abrasive tools such as grinders, drills and other 
tools are capable of making sparks that can ignite 
flammable materials.

Always operate the air compressor a safe distance 
away from flammable items. Use in well-ventilated 
areas.

Never exceed the maximum rated pressure.

FIRE

WARNING

EXPLOSION

Summary of Contents for 60050SCR

Page 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OWNER S MANUAL CALIFORNIA AIR TOOLS 60050SCR 5 0 HP 60 GALLON 220 VOLTS 60 HERTZ WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Page 2: ...________________10 MAINTENANCE _________________________________11 Draining the Air Tank ___________________________11 Changing the Air Filter__________________________11 Testing for Leaks ______________________________11 Cleaning _____________________________________11 STORAGE ______________________________________11 TROUBLESHOOTING ____________________________12 SPECIFICATIONS___________________...

Page 3: ...he grounding plug is able to result in a risk of electric shock When repair or replacement of the in a risk of electric shock When repair or replacement of the cord or plug is required do not connect the grounding wire cord or plug is required do not connect the grounding wire to either flat terminal The wire with insulation having an to either flat terminal The wire with insulation having an oute...

Page 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Page 5: ...chments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If spar...

Page 6: ...de important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PRODUCT LABEL A B C D E F G H AIR COMPRESSOR ...

Page 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Page 8: ...nd impair proper operation Always use the air filter properly installed Ventilation When using the air compressor in an enclosed room install a fan for ventilation BTU British Thermal Unit 12800 Ambient Temperature Use at ambient temperatures of 36 F to 104 F Using at less than 36 F will cause unit failure or freezing Use caution to minimize risk of fire or explosion It is normal for the air compr...

Page 9: ...ore connecting to the power supply to the power supply Ensure that you have a sufficient electrical supply for Ensure that you have a sufficient electrical supply for supporting the requirements of the motor supporting the requirements of the motor Improper installation of the grounding plug is able to result Improper installation of the grounding plug is able to result in a risk of electric shock...

Page 10: ...n cause severe burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to ...

Page 11: ...gned to reduce noise and help prevent particulates in the air from entering and damaging the air compressor After being used for a period of time the air filter will become clogged This will reduce the air intake capabilities of the air compressor reducing performance Therefore the air filter must be replaced regularly 1 Open the lid of the air filter and remove the old air filter element 2 Replac...

Page 12: ...re burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Replace capacitor The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to specifications An extension cord that is too thin or too long can cause a voltage drop and cause the motor to overheat Allow the motor to cool down Ens...

Page 13: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Page 14: ...This warranty gives you specific legal rights and you may also have other rights which may vary from state to state Disclaimer of Other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any ...

Page 15: ...ed by California Air Tools Inc 9 Repairs without California Air Tools prior written approval 10 Incorrect voltage improperly wired or failure to have a certified licensed electrician install the air compressor 11 Acts of God The application of these exclusions will be determined at the sole discretion of California Air Tools Inc Maintenance Trouble Shooting WWW CALIFORNIAAIRTOOLS COM Go to the Mai...

Reviews: