background image

12

Customer Support: 1-866-409-4581

AIR COMPRESSOR

MAINTENANCE 

Draining the Air Tank 

The frequency at which you should drain the air tank depends on 
the environmental conditions and the amount of operating time 
logged. The average draining frequency is every 1 to 2 days. 

1.

 Place the air compressor above a container capable of holding 

water.  

2.

 With compressed air in the air tank, slowly turn the drain valve 

knob to the forward (open) or straight position.                    
The water in the air tank will drain out.  

3.

 After all of the accumulated water has drained out, turn the 

drain valve knob to the closed or left position in order to avoid 
leakage. 

4. 

Draining the air tank protects parts from rust and corrosion. 

 

Cleaning or Changing the Air Filter 

The air filter is designed to reduce noise and  help prevent 
particulates in the air from entering and damaging the air 
compressor. 

After being used for a period of time, the air filter will become 
clogged. This will reduce the air intake capabilities of the air 
compressor, reducing performance. Therefore, the air filter must 
be cleaned or replaced regularly. 

1.

 Open the lid on the air filter, then remove the air filter element. 

2.

 To clean the element blow off or brush off the dirt and dust. 

3.

  If clogged, replace with a new air filter. 

 

Testing for Leaks 

Make sure all connections are tight. Do not overtighten. 

A small leak in any hose or pipe connection will reduce the air 
compressor's performance. 

To test for small leaks, spray a small amount of soapy water on 
the area suspected of leaking. If the soap bubbles, replace the 
broken part. 

 

Cleaning 

Clean items with a soft brush, or wipe with a moistened cloth 
using a biodegradable solvent. 

Do not use flammable liquids such as gasoline or alcohol. Always 
keep parts clean from dirt and dust for better performance.

 

Pressure Switch 

The pressure switch is factory pre-set to shut off at between 

115 - 120  PSI and to re-start at between 85 -90 PSI 

 

 

 

STORAGE 

Before storing for a prolonged period of time: 

 

1.

 Turn off the power supply. 

2.

 Disconnect the power cord from the power supply and wrap 

the power cord around the air compressor handle to reduce 
the risk of damage. 

3.

 Pull the relief valve and release all the pressure from the air 

tank. Drain the water from the tank through the drain valve. 

4.

 Clean the air compressor to remove all dirt and dust. 

5.

 Cover the air compressor with a cover to protect the unit from 

dust and moisture. 

6.

 Do not stack or store any items on top of or around the air 

compressor. Damage could occur.

Summary of Contents for 8010ALFCAD

Page 1: ...COMPRESSOR OWNER S MANUAL CALIFORNIA AIR TOOLS 8010ALFCAD 1 0 HP 4 00 CFM 40 PSI 3 00 CFM 90 PSI 8 0 GALLON ALUMINUM TANK W LONG LIFE MOTOR PUMP AUTOMATIC DRAIN VALVE WWW CALIFORNIAAIRTOOLS COM Custom...

Page 2: ...________________12 Draining the Air Tank ___________________________12 Changing the Air Filter__________________________12 Testing for Leaks ______________________________12 Pressure Switch __________...

Page 3: ...RTOOLS COM Please provide the information below Model number and Serial number and specifications shown on the Model number Serial number plate Part number or numbers shown in the parts list section o...

Page 4: ...the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are c...

Page 5: ...hments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder...

Page 6: ...e labels provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed...

Page 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR...

Page 8: ...top rear of motor head Screw the air filter into the motor head port hand tighten only Install the Wheel Kit 1 Slide Bolt 47 tthrough Wheel 46 2 Slide the Bolt 47 through wheel support hole located o...

Page 9: ...ter precipitation dust or particulates are in the air This will damage the motor and impair proper operation IMPORTANT Always use the air filter properly installed Use caution to minimize risk of fire...

Page 10: ...ing plug OPERATING THE AIR COMPRESSOR Save this manual for future reference Introduction This air compressor features a compact structure stable performance a high airflow rate easy operation and main...

Page 11: ...ch hot surfaces because they can cause severe burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air co...

Page 12: ...er element 2 To clean the element blow off or brush off the dirt and dust 3 If clogged replace with a new air filter Testing for Leaks Make sure all connections are tight Do not overtighten A small le...

Page 13: ...indings are burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Contact Customer Support The motor does not start or starts slowly Low voltag...

Page 14: ...rth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gau...

Page 15: ...by California Air Tools Inc 7 Normal wear 8 The use of accessories or attachments not recommended by California Air Tools Inc 9 Acts of God The application of these exclusions will be determined at t...

Page 16: ...ressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties that may arise...