INSTRUCTIONAL MANUAL
2750L-P/4500L-P/6000L-P
August, 2001
Rev. K
-67-
Table 3-15
STATUS BYTE VALUES
SRQ
1
0
REPORTED MESSAGE
CAUSE
64
0
65
1
66
2
67
3
68
4
69
5
70
6
71
7
72
8
73
9
74
10
75
11
76
12
77
13
78
14
90
26
91
27
92
28
93
29
94
30
95
31
96
32
97
33
98
34
99
35
100
36
63
40
AMP A FAULT
AMP B FAULT
AMP AB FAULT
AMP C FAULT
AMP AC FAULT
AMP BC FAULT
AMP ABC FAULT
CRL FAULT
TEMP A FAULT
TEMP B FAULT
TEMP AB FAULT
TEMP C FAULT
TEMP AC FAULT
TEMP CB FAULT
TEMP ABC FAULT
RNG RANGE ERROR
AMP RANGE ERROR
FRQ RANGE ERROR
PHZ RANGE ERROR
CRL RANGE ERROR
RMPA RANGE ERROR
SYNTAX ERROR
BUS LOCAL ERROR
EXT SYNC ERROR
CPU MEMORY FAULT
DMA OVERFLOW ERROR
STA OK
Overload or sense line fault
Overload or sense line fault
Overload or sense line fault
Overload or sense line fault
Overload or sense line fault
Overload or sense line fault
Overload or sense line fault
Output current exceeds program value
Amplifier overtemperature
Amplifier overtemperature
Amplifier overtemperature
Amplifier overtemperature
Amplifier overtemperature
Amplifier overtemperature
Amplifier overtemperature
RNG value greater than highest range
AMP value greater than RNG value
FRQ value is less than 45 or greater than 2000 Hz
PHZ value greater than ±999.0
CRL value greater than maximum value
DLY, STP or VAL values wrong
Wrong string SYNTAX
Remote message sent while in local mode
No external sync input or signal not between 45 and 2000 Hz
CPU failed self-test
Remote message greater than 256 bytes
The response after SRQ2 is included in a setup string and the
execution of the string or measurement is completed.
No problems
3.8
REMOTE OPERATION WITH MATE CIIL
The 4500L-3P and 2750L-3P are the only Power System configuration with the MATE CIIL option. When the
4500L-3P or the 2750L-3P is configured to operate with CIIL as the principal language, the alternate language
is APE. Refer to Section 3.7 for information on the APE program syntax. Using CIIL, the power source will
accept OP codes, the noun ACS (AC SIGNAL) and noun modifiers to program the operating parameters of
voltage, frequency, phase and current limit in a setup string. In addition, a number of OP codes cause the
power source to perform a specific task such as reset and confidence testing. Figure 3-6 is a summary of the
CIIL program syntax.