INSTRUCTIONAL MANUAL
2750L-P/4500L-P/6000L-P
August, 2001
Rev. K
-12-
Frequency:
360 to 440 Hz (Tracks the main outputs)
Phase:
Tracks the phase A output with Phase D
Distortion:
1% THD maximum with linear load
Line
Regulation:
±0.1%
for
10%
line
change
Load Regulation:
±10% from no-load to full-load
MATE (MT option)
CIIL
language
DFI
connector
Confidence Test
(Tests 3 phases for output, oscillator drive, phase relationship, frequency and current
limit.)
MIL-704D (704D option)
Performs all sections of MIL-STD-704D
2-PHASE (2P):
2-phase operation
RTCA/DO-160C
(DO160C option)
Performs all sections of RTCA/DO-160C
SYSTEMS
MODEL
POWER PER PHASE
MAX CURRENT PER PHASE (135V RANGE)
(35
°
C)
UP
(35
°
C)
UP
9000L-1P
10000
9000
74.08
66.66
13500L-1P
15000
13500
111.2
100.0
27000L-1P
30000
27000
222.2
200.0
9000L-2P 5000 4500 37.04
33.34
9000L-3P
3333
3000
34.68
22.22
12000L-3P 4000
29.62
12000L-1P 12000
88.88
13500L-3P
5000
4500
37.04
33.34
18000L-3P 6000
44.44
18000L-1P 18000
133.4
27000L-3P
10000
9000
74.08
66.66
Summary of Contents for 2750L-P Series
Page 119: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 115 Figure 6 1 MODULE LOCATION...
Page 138: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 134 Figure 14 EMERGENCY VOLTAGE...
Page 148: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 144 FIGURE 2...