INSTRUCTIONAL MANUAL
2750L-P/4500L-P/6000L-P
August, 2001
Rev. K
SECTION 1
INTRODUCTION AND SPECIFICATIONS
1.1 INTRODUCTION
This instruction manual contains information on the installation, operation, calibration, and maintenance of all power
systems that use the 2750L-P,4500L-P and 6000L-P.
1.2 GENERAL
DESCRIPTION
This power system is a high efficiency power source that provides a low distortion output. The output can be configured
in either a single or three-phase configuration.
A number of Power Sources can be configured to supply full output power up to 27000VA. Table 1-1 shows the output
VA per phase for each of the available power system models. The table also shows that increased power is available
at a reduced operating temperature of 35
°
C.
OUTPUT
VA
NUMBER
MODEL
PER PHASE
PHASES
50
°
C 35
°
C
2750L-1P 2700
3000 1
2750L-3P 900
1000 3
Number
of
power sources
4500L-1P 1
4500
5000
1
4500L-3P 1
1500
1667
3
6000L-1P 1
5330
6000
1
6000L-3P 1
1770
2000
3
9000L/2-1P 2
9000
10000
1
9000L/2-3P 2
3000
3333
3
12000L-1P 2
10600
12000
1
12000L-3P 2
3540
4000
3
13500L/3-1P 3 13500
15000
1
13500L/3-3P 3 4500
5000
3
27000L/6-1P 6 27000
30000
1
27000L/6-3P 6 9000
10000
3
Table 1-1:
OUTPUT VA PER PHASE
Summary of Contents for 2750L-P Series
Page 119: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 115 Figure 6 1 MODULE LOCATION...
Page 138: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 134 Figure 14 EMERGENCY VOLTAGE...
Page 148: ...INSTRUCTIONAL MANUAL 2750L P 4500L P 6000L P August 2001 Rev K 144 FIGURE 2...