INSTRUCTIONAL MANUAL
2750L-P/4500L-P/6000L-P
August, 2001
Rev. K
-55-
EXTENSION
ARGUMENT DEFINITION
HEADER
of the output voltage
ELT
Used with TLK to request total
accumulated runtime.
CUR
A, B, C
Used with TLK to request measurement
of the output load current.
MOD
PHS
1 or 3
Program the output phase configuration
PWR
A, B, C
Used with TLK to request measurement
of the True output power.
APW
A, B, C
Used with TLK to request measurement
of the Apparent output power
PWF
A, B, C
Used with TLK to request measurement
of the output power factor.
PZM
A, B, C
Used with TLK to request measurement
of the output phase angle.
FQM
Used with TLK to request measurement
of the output frequency.
NOTE: If Extension does not follow the header, the argument will be applied to all phases.
3.7.5
TO PROGRAM OUTPUT VOLTAGE AMPLITUDE (AMP)
The AMP header with the optional A, B or C extension is used to identify the amplitude command. The argument is a
numeric data field from 0.0 to the limit set by the RNG value. An attempt to program a value higher than this value will
generate an error and a SRQ on the GPIB.
The following ASCII strings will program the voltage given in the left column:
A,B,C 0.0 volts
AMP0
or
AMPA0AMPB0AMPC0
A,B,C 10.5 volts
AMP10.5
or
AMP1.05E1 or
AMP105E-1
A,B,C 100 volts
AMP100
or
AMP100.0
or
AMP1E2
A,B = 110.5, C = 115
AMPA110.5AMPB110.5AMPC115 or AMP110.5AMPC115
3.7.6
TO PROGRAM FREQUENCY (FRQ)
The FRQ header is used to identify the following numeric data as frequency.
The following string will program the frequency to 60.56 Hz.
FRQ 60.56
3.7.7
TO PROGRAM PHASE ANGLE (PHZ)
The PHZ header with the optional A, B or C extension is used to identify the following numeric data as phase. The PHZ
header sent with no extension will program the B and C outputs in phase with phase A. The phase of the A output will
lead the EXT SNC signal by the value programmed.