iL Series User Manual
72
Rev B
California Instruments
Step
Procedure
Indication
Action
1
Turn off AC mains,
disconnect load and
connect sense terminals
for local sensing.
2
Remove the top cover as
follows:
Remove 9 screws from the
top and 3 screws from the
each side.
Then lift the cover straight
up being careful of the lip
on the front of the cover.
3
Turn on supply and verify
that AC power is on by
checking for any
observable indication (i.e.
fan running, display on)
Is AC power ON?
If not, Check input fuses F1,
F2, F3 on rear panel. Check
input line filter FL1.
4
There should be a clicking
sound as the 3 current limit
relays on the A9 assembly
energize.
Do the relays
energize?
If not, Check A9F2, A9F3,
A9F4 1 amp slow blow.
Check A9F1 1/4 amp normal
blow.
5
About 1-3 seconds after
the 3 current limit relays
energize, relay K1 should
energize.
Does relay K1
close?
Are fans running?
If not, Check C1 for 300
VDC. 300 VDC is initially
supplied via 3 relays, fuses
and resistors at bottom of A9
board.
6
Bias voltages are supplied
from the A10 Auxiliary
power supply board. The
300 VDC is used to
generate the bias voltages.
Check the bias voltage at
the connectors along the
top circuit side edge of the
A10 board.
See Table 3-4 in
next page for
signal pin
voltages.
7
If no bias voltages are
present check fuse F1 on
A10 board, subminiature
type 1 amp.
Is display on?
Check +5 volt HPIB bias
supply from A10 Aux PS &
A5 relay/sense assy. A10J6
pins 1 and 2.
8
Use front panel keys to
program voltage and
current to full scale and
frequency for 60 Hz.
Use DVM to measure
output voltage at output
terminal block, TB2.
Is output voltage
within
specification?
If voltage at TB2 is correct
but front panel reading is
incorrect, A8 DSP assembly
is most likely at fault.
If voltage at TB2 is correct
but outside specification -
unit requires calibration.
9
Is one phase
missing?
Check F1, F2, F3 15 amp
fuses in 300 VDC line on A4
mother board.
Summary of Contents for 3000iL
Page 9: ...iL Series User Manual California Instruments Rev B ix page intentionally left blank...
Page 10: ......
Page 37: ...iL Series User Manual California Instruments Rev B 27...
Page 89: ...iL Series User Manual California Instruments Rev B 79 Figure 23 AC Power Source Block Diagram...
Page 93: ...iL Series User Manual California Instruments Rev B 83 Figure 25 AC Input Board Parts Location...