User and Programming Manual - Rev H
California Instruments
P Series
May 2000
3
2. Specifications
All specifications at 25
±
1
°
C unless noted otherwise.
2.1 Electrical
2.1.1 Input
Line Voltage:
85V to 264V maximum
100V to 240V nominal
Line Current:
25 A RMS max. (1251RP)
Line Frequency:
47-63 Hertz
Efficiency:
80% (typical) depending on line and load
Power Factor:
0.95 or greater typical
Inrush Current:
70 A peak max. at 260V input
Hold-Up Time:
20 ms (with no effect on output)
Isolation Voltage:
Input to output = 2200 VAC, input to chassis = 1350 VAC
2.1.2 Output
Voltage Range:
Low Range is 0 to 135 V rms
High Range is 0 to 270 V rms
Voltage Resolution:
0.1 volt
Voltage Accuracy:
±
1% or range, 50 to 60 Hz
±
2% at 400 Hz
Line & Load Regulation:
2%of FS on low range, 1% of FS on Hi range
Voltage Distortion:
1% max. THD at 50/60 Hz
Total Power:
800VA maximum at full scale voltage either range (model 801P)
1000VA maximum at full scale voltage either range (model 1001P)
1250 VA maximum at full scale voltage either range(model 1251P)