User and Programming Manual - Rev H
California Instruments
May 2000
P Series
6
Front panel mounted
output connections:
CEE 7/7
European socket
US domestic
Dual 120V line socket
2.3 Environmental
Operating Temp:
0 degrees to +40 degrees Celsius.
Storage Temp:
0 degrees to +70 degrees Celsius.
Humidity:
Operating:
≤
90% RH up to 40
°
C.
Storage:
≤
90% RH up to 40
°
C,
≤
75% RH up to 70
°
C.
Creepage and
Clearance:
Rated for Pollution Degree 2.
Insulation:
Rated to Installation Category(Overvoltage Category) II
Vibration:
Designed to meet NSTA 1A transportation levels.
Shock:
Designed to meet NSTA 1A transportation levels.
2.4 Regulatory
Electromagnetic
Designed to meet EN50081-2 and EN50082-2 European Emissions
Emissions and
and Immunity standards as required for the “CE” mark.
Immunity:
Acoustic Noise:
65 dBA maximum at 0% to 50% load, 75 dBA maximum greater than
50% load to 100% load. Measured at one meter.
Safety:
Designed to meet UL3111 and EN61010-1 European safety standards
as required for the “CE” mark.
2.5 Front Panel Controls
Controls:
Shuttle knobs:
Allows continuous change of Voltage, Frequency and Current limit.
Function keys:
Controls Output state, Voltage range and Display mode.