background image

LOAD

LINE

110/220VAC

POWER 

SOURCE

6” VERTICAL

CONTROL

CENTER

POOL

RETURN

SPA

RETURN

FROM

POOL

FROM

SPA

The 

Platinum System cell MUST 

be installed horizontally, with the ports down, as the last 

piece of pool equipment in line, on the return to the pool, after the heater. (See illustration 

on next page) the design of the cell forms a natural gas trap. Even though the Platinum 

system has an internal flow sensor, this installation provides a secondary safety feature to 

prevent gas build-up within the system. 

Note

: The inlet is labeled on the cell housing with 

an arrow pointing up. The cell housing should be located 6 inches above the height of 

plumbing: in the event there is no heater, the cell should be located above the height of 

the filter inlet and outlets. Any standard PVC cement may be used. Always use PVC cleaner 

to prep all glue joints. Allow adequate drying time before turning on the pump. All of the 

fittings are 2 inch PVC, and if necessary can be reduced to 1½ inch PVC. The cell has a 10 

foot power cord, and cannot be modified; use precaution to place the cell housing within 

reach of the Platinum Control Center. 

The 

Platinum Control Center is shipped wired for 220V

. The control center can be 

converted to 120V in the field by a pool professional or certified electrician; a wiring 

diagram for making the conversion in included with each Platinum system. Questions on 

this process should be directed to CaliMar tech support at (888) 635-0330. 

T

he Platinum system is designed to power on ONLY when the primary pump is 

operating and should be wired to the load side of the time clock. 

It must be grounded 

with an 8AWG bonding wire from the lug (see illustration on page 15 ) on the bottom of 

the Control Center to a grounding rod (this is necessary to protect the integrity of the 

electronic systems). 

Note: Platinum systems are not recommended to be installed on 

pools using a stainless steel liner or stainless steel plumbing.

Installation Preperation

12

Summary of Contents for CMARSSG20-5

Page 1: ...CMARSSG20 5 CMARSSG40 5 CMARSSG60 5 20 000 Gallon System 40 000 Gallon System 60 000 Gallon System MODELS OWNER S MANUAL...

Page 2: ...critical to proper operation of the unit Problems or equipment failures resulting from the failure to maintain pool water chemistry in accordance with guidelines set forth in the Owner s Manual will v...

Page 3: ...lorinator Works 7 Water Preperations and Tips on Water Chemistry 7 Salt When and How to Add It 9 Salt Convertion Table 10 Chlorinator Installation 11 Installation Preperation 12 Installation Procedure...

Page 4: ...lectrician if you cannot verify the receptacle is protected by a GFCI 4 Do not bury cord Locate cord to minimize abuse from lawn mowers hedge trimmers and other equipment 5 WARNING To reduce the risk...

Page 5: ...ps To prevent cell damage and or personal injury do not in any way interfere with this system which has been designed for your protection CHEMICAL USE HAZARD To avoid personal injury when working with...

Page 6: ...ne generator is subject to the specifications of each body of water and should be carefully evaluated for best results Where heightened chlorine demand exists due to warmer climates humidity high bath...

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ...760 800 1800 147 182 220 258 293 330 367 403 440 477 513 550 587 523 660 697 733 2000 133 166 200 234 267 300 333 367 400 433 467 500 533 567 600 633 667 2200 120 150 180 210 240 270 300 330 360 390 4...

Page 11: ...rature LOCATED ON BOX The following tools will be required to install the Platinum system Screwdriver Level Hacksaw or PVC cutter Wire Stripping Tool Electric Drill 8AWG Copper Bonding Wire INSTALLING...

Page 12: ...urning on the pump All of the fittings are 2 inch PVC and if necessary can be reduced to 1 inch PVC The cell has a 10 foot power cord and cannot be modified use precaution to place the cell housing wi...

Page 13: ...hole slots on the wall bracket and allow the unit to hang freely Your Platinum Control Center is now mounted 5 Connect 8AWG bonding wire not included between the grounding rod and the grounding lug lo...

Page 14: ...d allow the cell to be removed for cleaning when neces sary 1 Balance your water chemistry according to the Water Chemistry Parameters shown on page 8 Add the proper amount of salt and circulate 24 ho...

Page 15: ...etween the cell blades The clear cell housing makes the monitoring of chlorine production and scale build up easy and visually accessible Control Center Functions 1 Sanitizer Output Lights shows level...

Page 16: ...used to offset out of the ordinary conditions unusual weather or extremely high bather load Unlike other chlorinators the Platinum is able to produce chlorine at all settings on the Sanitizer Output...

Page 17: ...ockwise direction Be careful not to over tighten 8 Re start your pump any loosened calcium will probably be brushed off with the water flow Cell Maintenance How and When to Clean Your Cell Although th...

Page 18: ......

Page 19: ...m Status light is ashing service light is yellow solid Increase Salt level by adding salt according to chart on Page 10 High Phosphates Metals High nitrate level Metals present in pool water Contact P...

Page 20: ...ave an experienced pool professional or an electrician con rm that the voltage is existent and correct Circuit breaker may be tripped Check the circuit breaker located on the control center box and re...

Page 21: ...21...

Page 22: ...Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 22...

Page 23: ...7 Grounding Lug 1 7 PC130 D1 10 Strain Relief 1 8 PC114 D2 10 Circuit Breaker 1 9 PC104 C3 2 Control Center Cover 1 10 PC123 D 2 1 Control Center Label 1 11 PC105 C3 5 On O Switch 1 12 CE107 C3 6 O Ri...

Page 24: ...tors com Register your warranty online sgschlorinators com warranty Visit us online www sgschlorinators com Manufactured by Saline Generating Systems LLC Record the Following Information Keep for Your...

Page 25: ......

Reviews: