background image

Safety Instructions & Precautions

continued

SAVE THESE INSTRUCTIONS

ELECTRICAL HAZARD

• 

All Platinum systems are shipped from the factory wired for 220 Volts.

• To reduce risk of electrical shock make sure all power to pool equipment area is off prior 

to any installation or removal of Platinum System components.

• Immediately replace damaged Control Center cord.

• Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers 

and other equipment.

• Severe shock or injury will likely occur as a result of drill or drill cord coming in contact 

with water. Never allow electric drill or cord to come in contact with water. Only plug drill 

into a Class A (5 Millampere Trip) protected Ground Fault Circuit Interrupter (GFCI) in 

accordance with the National Electrical Code Section 680 (USA ONLY). Please see your 

drill owner’s manual for further safety precautions.

• Install the Control Center at least 10 feet from the inside walls of a pool to prevent any 

possibility of the unit coming in contact with water.

• The Platinum Chlorinator has been designed with an internal electronic flow sensing 

tab. This device automatically switches the power to the electrolytic cell “OFF” when the 

water through the cell stops. To prevent cell damage and/or personal injury, do not in any 

way interfere with this system which has been designed for your protection.

CHEMICAL USE HAZARD

• To avoid personal injury when working with pool chemicals, always wear rubber gloves 

and eye protection, and work in a well-ventilated area. Use caution when choosing a 

location to open and use chemicals as they may damage any surface to which they come 

in contact.

• The addition of certain chemicals can reduce the effectiveness of chlorine. Always make 

sure that proper residual chlorine levels are maintained to avoid personal injury.

• This product produces chlorine. Individuals with any type of chlorine sensitivity should   

take the appropriate precautions to avoid injury or illness.

Important Notice:

 

Attention Installer:

 This manual contains important information 

about the installation, operation and safe use of this product. Before installing this 

product, read and follow all warning notices and instructions which are included. This 

information should be given to the owner and/or operator of this equipment.

WARNING: IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY TO PERSONS. READ AND FOLLOW ALL

INSTRUCTIONS. 

Failure to follow safety warnings and instructions can result in severe 

injury, death, or property damage. Call (888) 635-0330 or go to www.calimarpool.com for 

additional free copies of these instructions.

5

Summary of Contents for CMARSSG20-5

Page 1: ...CMARSSG20 5 CMARSSG40 5 CMARSSG60 5 20 000 Gallon System 40 000 Gallon System 60 000 Gallon System MODELS OWNER S MANUAL...

Page 2: ...critical to proper operation of the unit Problems or equipment failures resulting from the failure to maintain pool water chemistry in accordance with guidelines set forth in the Owner s Manual will v...

Page 3: ...lorinator Works 7 Water Preperations and Tips on Water Chemistry 7 Salt When and How to Add It 9 Salt Convertion Table 10 Chlorinator Installation 11 Installation Preperation 12 Installation Procedure...

Page 4: ...lectrician if you cannot verify the receptacle is protected by a GFCI 4 Do not bury cord Locate cord to minimize abuse from lawn mowers hedge trimmers and other equipment 5 WARNING To reduce the risk...

Page 5: ...ps To prevent cell damage and or personal injury do not in any way interfere with this system which has been designed for your protection CHEMICAL USE HAZARD To avoid personal injury when working with...

Page 6: ...ne generator is subject to the specifications of each body of water and should be carefully evaluated for best results Where heightened chlorine demand exists due to warmer climates humidity high bath...

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ...760 800 1800 147 182 220 258 293 330 367 403 440 477 513 550 587 523 660 697 733 2000 133 166 200 234 267 300 333 367 400 433 467 500 533 567 600 633 667 2200 120 150 180 210 240 270 300 330 360 390 4...

Page 11: ...rature LOCATED ON BOX The following tools will be required to install the Platinum system Screwdriver Level Hacksaw or PVC cutter Wire Stripping Tool Electric Drill 8AWG Copper Bonding Wire INSTALLING...

Page 12: ...urning on the pump All of the fittings are 2 inch PVC and if necessary can be reduced to 1 inch PVC The cell has a 10 foot power cord and cannot be modified use precaution to place the cell housing wi...

Page 13: ...hole slots on the wall bracket and allow the unit to hang freely Your Platinum Control Center is now mounted 5 Connect 8AWG bonding wire not included between the grounding rod and the grounding lug lo...

Page 14: ...d allow the cell to be removed for cleaning when neces sary 1 Balance your water chemistry according to the Water Chemistry Parameters shown on page 8 Add the proper amount of salt and circulate 24 ho...

Page 15: ...etween the cell blades The clear cell housing makes the monitoring of chlorine production and scale build up easy and visually accessible Control Center Functions 1 Sanitizer Output Lights shows level...

Page 16: ...used to offset out of the ordinary conditions unusual weather or extremely high bather load Unlike other chlorinators the Platinum is able to produce chlorine at all settings on the Sanitizer Output...

Page 17: ...ockwise direction Be careful not to over tighten 8 Re start your pump any loosened calcium will probably be brushed off with the water flow Cell Maintenance How and When to Clean Your Cell Although th...

Page 18: ......

Page 19: ...m Status light is ashing service light is yellow solid Increase Salt level by adding salt according to chart on Page 10 High Phosphates Metals High nitrate level Metals present in pool water Contact P...

Page 20: ...ave an experienced pool professional or an electrician con rm that the voltage is existent and correct Circuit breaker may be tripped Check the circuit breaker located on the control center box and re...

Page 21: ...21...

Page 22: ...Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 22...

Page 23: ...7 Grounding Lug 1 7 PC130 D1 10 Strain Relief 1 8 PC114 D2 10 Circuit Breaker 1 9 PC104 C3 2 Control Center Cover 1 10 PC123 D 2 1 Control Center Label 1 11 PC105 C3 5 On O Switch 1 12 CE107 C3 6 O Ri...

Page 24: ...tors com Register your warranty online sgschlorinators com warranty Visit us online www sgschlorinators com Manufactured by Saline Generating Systems LLC Record the Following Information Keep for Your...