background image

10

Installation

Figure 13 

Step 

7

Gate Travel Limit

This controls the position of where the gate stops when it opens and closes. 

The travel limit adjustment section is located inside the gate opener.

Youtube 

More detail on travel limit programming: https://youtu.be/_DeVM5dgZPs 

-Push the metal lock back in when done.

-Push and hold the metal lock back and turn up or both wheels to adjust the position of where 

the gate opens and closes. Figure 13

Finished! 

You are now finished installing your gate operator.

Summary of Contents for CM3-DCNB

Page 1: ...www calimetco com 9949 Hayward Way South El Monte CA 91733 Tel 626 452 9009 Sliding Gate Operator CM3 DCNB Instruction Manual ...

Page 2: ...ly maintained Read the owner s manual on how to maintain your gate Have a certified service technician make repairs or install gate operator hardware The gate entrance should be used for vehicles only Pedestrians should use a seperate entrance Keep these instructions Product Specs Main AC Supply 110V AC System Operating Voltage 24V DC Maximum Output Current 30 amp Fuse 24V DC 30 amp Remote Control...

Page 3: ...ates Primary Device A B1 B2 D Secondary Device one required A B1 B2 D E Swing Gates Primary Device A B1 B2 C D Secondary Device one required A B1 B2 C D E REQUIRED ENTRAPMENT PROTECTION A Inherent built in Entrapment protection System B1 Non contact sensor such as a photo eye or equivalent B2 Contact sensor such as edge sensor or equivalent C Inherent adjustable clutch or pressure relief device D ...

Page 4: ...e gate while operating the controls Controls intended to be used to reset an operator after 2 sequential activations of the entrapment protection device or devices must be located in the line of sight of the gate Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use For gate operators utilizing a non contact sensor in accordance with 30A 1 1 1 See instruct...

Page 5: ...e either the Front or Rear Position If you re not sure choose the Front position Front Position Rear Position or If you chose Rear Position install the chain using figure 2 Install the operator INSIDE the property Install the gate operator on the inside of the property and behind the gate DO NOT install the operator on the outside of the gate where the public has access to it ...

Page 6: ...5 Figure 3 Figure4 Installation The gate operator should be 5 inches away from the gate The chain should be 5 inches above the base Gate Operator Distance from Gate and Base ...

Page 7: ... 6 Installation Contact local underground utility locating companies before digging more than 12 inches deep to avoid damaging underground power gas or other utility lines Wedge Anchor Size of concrete base A minimum of 2 on each side of the operator is recommended Step 2 Installing the Base The base also known as a pad is a raised platform We recommend using a concrete base 1 2 x 3 1 2 ...

Page 8: ...nch 2 5 cm of sag for every 10 feet 3m of chain length Chain should not be too tight or too loose Chain should be straight and not bent at an angle If the chain is too loose remove links from the chain until you get your desired length Figure 7 Figure 8 NOTE Make sure the chain is straight and not bent Incorrect installation can cause the gate operator to malfunction and potentially get damaged Fi...

Page 9: ...ated circuit for power supply 3 When the power is connected turn the power switch to the ON position Installation Step 4 Connecting the Power Power Battery See which direction your gate opens when viewed from the inside exit side Figure 10 Step 5 Open Direction Dip Switch 6 Figure 10 on the bottom of the gate operator circuit board controls the open direction ON opens to the right OFF opens to the...

Page 10: ...your gate about 21 from the ground 4 Press the orange button on the photo eye to turn on the infrared beam 5 Mount the reflector to the opposite side Make sure the infrared beam hits inside the circle of the reflector Figure 12 6 Press the orange button on the photo eye to turn off the infrared beam Plug photo eye cable here 9 Figure 11 Youtube Youtube video with more details on how to install the...

Page 11: ...stment section is located inside the gate opener Youtube More detail on travel limit programming https youtu be _DeVM5dgZPs Push the metal lock back in when done Push and hold the metal lock back and turn up or both wheels to adjust the position of where the gate opens and closes Figure 13 Finished You are now finished installing your gate operator ...

Page 12: ... Reset the pedal only when the operator doesn t work while using the remote control 1 Push the pedal downward from locked position and slightly move to the left 2 Allow the pedal rise up to the reset position and release the pedal Features EMERGENCY RELEASE The emergency release allows you to open the gate manually such as in cases where there is a power outage and there is no electricity ...

Page 13: ...ion B Unscrew the back of the remote control to gain access to the control board You should see 1 8 dip switches Each switch has 3 positions up middle bottom Flip these 1 8 switches to any position you d like C On the gate opener control board look for the same 1 8 dip switches and set the same combination as you did on the remote D Finished Note On switch SW10 KEY 1 and KEY 2 are used for the 2 b...

Page 14: ...bottom of the circuit board with the words DATA and DATA B Use a flathead screwdriver to release the 2 locks on the top of the green terminal C For conductor 1 connect the DATA on the MASTER circuit board to the DATA on the SLAVE circuit board D For conductor 2 connect the DATA on the MASTER circuit board to the DATA on the SLAVE circuit board E Use the flathead screwdriver to close the two locks ...

Page 15: ...14 Figure 16 Features Safety and Exit Loop This is an optional step If you wish to install a exit loop detector see figure 16 for the position of the safety and exit loops Entrapment Protection ...

Page 16: ...15 Features Control Board Layout This is a picture of the control board Use this for reference Youtube Circuit board Programming Guide https youtu be _7iBuKr1ZtY ...

Page 17: ...l to move gate to opposite direction Features DIP Switch Features There are 6 dip switches located at the bottom of the circuit board Each switch has a different feature 4 1 PASS Anti tailgating system When ON after a vehicle has cleared the safety loop the gate will start to close immediately If a second vehicle crosses the loop while the gate is closing the gate will stop The second vehicle must...

Page 18: ...ensors Figure18 Follow infrared control instructions to connect power Common wire is connected to Common pole signal wire is connected to OPEN or CLOSE pole Note Check Photo eye connection if hear a long beep from Circuit board the when motor is ON ...

Page 19: ...18 Features Installing an External Receiver External connectors are installed on the rear side of mainboard protector box Figure19 ...

Page 20: ...on causing the gate to reverse The open and close knobs determine the amount of force required to reverse the gate figure 21 We generally recommend leaving the knob at 75 or around a 3 00 position You may adjust the positions based on your needs If the gate reverses without touching an obstruction the ERD is too sensistive If the gate does not reverse when it hits an obstruction the ERD is not sen...

Page 21: ... 6 seconds by turning knob on DELAY 1 On your gate operator circuit board in the bottom turn Dip Switch 2 to the ON position Figure 22 2 On the gate operator circuit board adjust the delay by turning the second blue knob from 0 60 seconds Figure 23 Auto Close This allows your gate to automatically close after opening it Figure 22 20 ...

Page 22: ...21 Other 1 BAT 24V external Battery Connector 2 LOOP DETECTOR Only compatible with Calimet Loop detector device 3 RELAY 1 Signal light connector this light only turns on when door is in motion Features ...

Page 23: ...ON when STAND BY blinks when motor is on 11 B L POWER ON when back up battery is fully charged blinks when low battery 12 M S LINK Blinks when master slave communication is active 13 TIMER Blinks when TIMER is counting down to close automatically 14 OPENING ON when gate is in the open cycle 15 CLOSING ON when gate is in the close cycle 16 MON FAULT ON when photo eye has malfunctioned 17 MON OPEN O...

Page 24: ...9949 Hayward Way South El Monte CA 91733 Tel 626 452 9009 Alternate 626 482 3066 Fax 626 452 9010 Email info calimetco com www calimetco com ...

Reviews: