33
Circuit Board Light Status Chart
1.
Photocell Sensor Obstruction or Misalignment
-an object has crossed the photocell
infrared beam when the gate was closing. If nothing interrupted the beam, the photocell sensor
may be misaligned. Align photocell sensor with the reflector on the other side to fix the problem.
2.
Impact Detection
- The gate operator has a built-in impact sensor called the ERD. If the gate
collided with an object, the alarm will sound. If there was no collision, the ERD force may be set
too low. Increase the force to fix the issue. Another possible issue is that the chain may be bent
or not correctly aligned to the sprocket.
3.
Low Battery
- Battery is low. Recharge using solar panel or AC electricity. DCFP models only.
Alarm
The alarm will sound in these following situations:
Name
CL
Status/Light
ON when CLOSE input is activated
PED-SW
SAFETY
PHANTOM
EXIT LOOP
LIMIT1
LIMIT2
RADIO
RESET
POWER
B.L-POWER
M/S LINK
TIMER
OPENING
CLOSING
MON-FAULT
MON-OPEN
MON-CLOSE
ON when Stand By, OFF when SAFETY LOOP input is activated
ON when incoming signal is detected from a reverse loop (phantom)
ON when EXIT LOOP input is activated
ON when limit nut has reached the limit 1 switch
ON when limit nut has reached the limit 2 switch
ON when the RADIO input is activated
ON when circuit board has been RESET
ON when the gate operator is on standby, blinks when motor is on
ON when back up battery is fully charged, blinks when low battery
Blinks when master/slave communication is active
Blinks when TIMER is counting down to close automatically
ON when gate is in the open cycle
ON when gate is in the close cycle
ON when photo eye has malfunctioned
ON when
photocell sensor is monitoring the open cycle
ON when photocell sensor is monitoring the close cycle
ON when STAND BY, OFF when the STOP input is activated or foot pedal
is pressed down.
Summary of Contents for CM3