7
Recommended Gate Structure
Gate Structure
Confirm that the gate operator being installed is appropriate for the gate type, weight and size. The
gate should be mounted and moving freely. There should be little resistance in the movement of the
gate. The gate and post must be suitable for being automated. Check that the structure is sufficiently
strong and stable, and that its dimensions and weights conform to those listed in the specifications
table of this document. Any worn or damaged gate hardware must be repaired or replaced before
installing the gate operator.
Vehicular gates are to be constructed and installed in accordance with the ASTM F2200 construction
standards.
2 Guarded
Guide Rollers
2 Guarded
Guide Rollers
Warning signs on
both sides of the gate
U.L Listed Underground Conduit
for 110-120VAC electrical wires
Over-Travel
Stops on Both
Ends of the
Gate
Reinforced concrete base
3" maximum picket
width distance
V-Groove
V-Track
Wheels
Recommended Gate Structure
Screen mesh
across entire gate
Summary of Contents for CM3
Page 41: ......