Features
Main Board Light Status Chart
Other:
1
.
BAT: 24V external Battery Connector
2
.
LOOP
DETECTOR: Only compatible with Calimet Loop detector device.
3
.
RELAY-1: Signal light connector, this light only turns on when door is in motion
No.
Name
Status/Light
1
CL
ON when CLOSE input is activated
2
PED-SW
ON when STAND BY, OFF when the STOP input is activated or foot
pedal is pressed down.
3
SATETY
ON when Stand By, OFF when SAFETY LOOP input is activated
4
PHANTOM
ON when incoming signal is detected
5
EXIT LOOP
ON when EXIT LOOP input is activated
6
LIMIT1
ON when limit nut is activating the limit 1 switch
7
LIMIT2
ON when limit nut is activating the limit 2 switch
8
RADIO
ON when the RADIO input is activated
9
RESET
ON when circuit board is RESET
10
POWER
ON when STAND BY, blinks when motor is on
1
8