Connection diagram
Bord Control 811
Art.-Nr. H08 012 0811 01
CALIRA Electronic GmbH & Co. KG Lerchenfeldstraße 9 87600 Kaufbeuren-Neugablonz
Bord Control 811
Hauptschalter
12V
16A
10A
7A
7A
I
II
III
MadeinGermany
0
5pole
Tank II
Water pump
P
ump+1,5mm²
(Waste water)
BN ¾
5
GY 0
GN ½
YE ¼
WH 1
Tank
0
12
10
16
14
1/4
0
1/2
3/4
1/1
B5108056502
Made in Germany
Battery 12V
Tank I
Battery 12V
(start)
(supply)
0,25mm²RD
0,25mm²BU
0,25mm²PK
2A
20A
2A
20A
atleast2,5mm²
(Freshwater)
Connection
plug
Fuses must be assembled near to the
+poles of the batteries
5pole
3pole
5
max.
max.
7A
7A
+
+
max.
16A
***
max.
10A
+
Electric lines must be correct dimensioned to avoid voltage drops
and overload. The length of the line and the current are important
factors to determine the right wire cross section.
Use at least the values of the following recommendations.
Wire cross section recommendations
Length
til
1,5m
til
3,0m
til
6,0m
over 6,0m
Current
til 15/30Amp.
til 15/30Amp
til 15/30Amp
til 15/30Amp
Wire cross section
1,5/4,0mm²
2,5/4,0mm²
4,0/6,0mm²
6,0/10,0mm²
Insert the sensor into the hole in
the tank and fasten it with a screw
driver. Note the wire colours. The
edge of the rubber gasket is
pressed against the outer surface
of the tank. Inside the tank it forms
a rubber fold , which seals up the
hole sure.
Compose the sensor, insert the
screw with sealing compound
and fasten srews first only by
hand.
Drill holes with 9,5-10,0mm
diameter into the wastewater
tank.
Burr the holes from both sides.