background image

 

First start up  

1) 

Open the high and low pressure refrigerant valves. 

2) 

Open water switch and fill the hot water cylinder with water. 

3) 

Make sure that the cylinder is filled with water. 

4) 

Make sure that the temperature sensor is in the lower temperature 

probe pocket of the cylinder. 

5) 

Connect the power cable. 

6) 

Turn the system on at the control panel. 

7) 

The Controller is pre-set for Cylinder heating at 60°C. All you have to 

do is set the clock and if required, the timer 

(see Clock setting & Timer 

setting page 11 & 12).

 

 

 

 

Summary of Contents for KP-50

Page 1: ...Manual Model KP 50 300L Version March 2020...

Page 2: ...nstallation 4 Outdoor Unit Installation 5 Display Controller 6 First start up 7 Control panel 8 Key lock function 9 Mode select 10 Clock setting 11 Timer setting 12 Defrosting Water quality requiremen...

Page 3: ...and spider webs and don t block it off in any other way A restricted or blocked air flow can result in a higher power consumption or failure of the unit It is also very important that the compressor...

Page 4: ...d installed according to local rules and regulations The hot water cylinder is to be considered as a normal hot water cylinder Only the heating part is different The cylinder must be installed vertica...

Page 5: ...n flow to a drain or will be absorbed by the soil Flooding water cannot reach the base of the unit The outdoor unit should be fitted on feet on a level base or on a wall bracket Please avoid locations...

Page 6: ...behind the front panel together with the temperature sensor The controller needs to be connected to the outdoor unit with a 3 core cable cable not supplied The sensor cable could be cut to the require...

Page 7: ...linder is filled with water 4 Make sure that the temperature sensor is in the lower temperature probe pocket of the cylinder 5 Connect the power cable 6 Turn the system on at the control panel 7 The C...

Page 8: ...meter setting ROOM HEAT mode key lock Cylinder HEAT mode timer on Defrost mode timer off first 88 is setting temperature second 88 is current temperature setting temperature symbol for ROOM HEAT ROOM...

Page 9: ...9 Key Lock function When is on key lock function is on Press the button for 6 seconds to release key lock The key lock function will be back on after not touching any button for 30 seconds...

Page 10: ...t side is actual water temperature Press to change the set temperature Press button to go to the next mode ROOM CO OL mode Not at this model Press button to go to the next mode AUTO1 mode Not at this...

Page 11: ...11 Clock setting Press for 6 seconds and minute and will flash Press to change minutes Press and the hour will flash Press to change hour or or...

Page 12: ...ge minute of TIMER ON Press and the hour and flash Press to change hour of TIMER ON Press and the minute and flash Press to change minute of TIMER OFF Press and the hour and flash Press to change hour...

Page 13: ...e heat pump will resume working afterwards Depending on the ambient temperature and humidity this could occur several times Process of defrosting Water quality requirements PH Value 6 5 8 0 Electrical...

Page 14: ...Ambient sensor E11 Compressor over heat protection E03 Compressor exhaust sensor E12 Anti freeze protection in winter E04 Evaporator sensor E13 Water return sensor E05 Compressor return sensor E14 Use...

Page 15: ...r temp heat pump heated 0 C 60 Level against electric shock I Water proof grade IPX4 Heat pump unit Net weight kg 40 Net size L W H mm 900x310x550 Hot water cylinder Net weight kg 43 Net size mm 560X1...

Page 16: ...installer Warranty Calitec Hot Water Systems are provided with a 5 year warranty on the outdoor unit and 20 year warranty on the stainless steel hot water cylinder if installed through qualified inst...