Installing the Main Electronics Module
To install the MEM
Important:
Observe all precautions for handling of electrostatic sensitive devices.
CAUTION!
The back side of the MEM uses a metallic gasket designed to
protect against Electromagnetic emissions (EMI). This gasket has a sharp
edge and can cut your fingers. Use care when handling the MEM. See
below for an illustration of the proper handling method.
Refer to the figure below
for completing the following steps:
1.
Remove the MEM from its anti-static plastic blister pack container.
2.
Orient the board with the power connector positioned in the upper left hand corner of
the board.
3.
Position the board over the four mounting posts in each corner of the chassis.
4.
Place the board over the posts and secure with the four captive screws mounted in the
assembly.
5.
Plug in the power cord as shown. Route the power cord through the cord retainer tabs
on the left hand side of the enclosure. Leave the other end of the cord disconnected for
the time being.
Note:
Make sure the fiber end is clean and free from nicks or burrs.