Memory Discussion
The unit contains a non-volatile memory that does not use a battery. Call records in memory
will be retained even for indefinite power outages. The unit must have power in order to write
new call records. A record is written to memory for each phone call made regardless of
whether that information was recorded by the monitoring computer.
The memory stores a maximum of 248 call records. Once this is exceeded, the most recent
call record is added to the end of the memory while the oldest call record is removed. In other
words, only the last 248 calls are stored. The unit contains no warning mechanism to alert the
user that the memory is full.
Only “End of call” records are written to memory. Even if the unit is set to deliver only “Start
of call” records to the computer, the “End of call” record will be still written to memory.
Refer to page 8 and page 12 for a discussion on setup toggles for “Start” and “End of Call”
records.
The following memory commands are the same as listed on page 10.
?
List number of calls records in memory.
F
List all call records in memory.
\
List last call record.
>
List the next call record.
<
List the previous call record.
-
(Dash)
Stop listing call records. (Since the memory processor cannot send and receive
data simultaneously you may need to press this key a few times to stop listing)
Y
Erase all calls in memory. Type “
Y
” once to prompt “Erase?” and another “
Y
” to
proceed. Allow approximately 27 seconds to erase memory and return “OK”