40
SECTION V
SUPPLEMENTAL INFORMATION
Specifications
Supply Voltage:
9 VDC, center negative
Supply Current:
Less than 250 mA
Loop Current Draw:
Less than 1 mA
Loop Voltage:
30 to 105 VDC
Ringing Voltage:
60 to 130 VAC
Insertion Loss:
Less than 0.3 dB
Voltage Drop:
2.7 VDC at 20 mA loop current
Ringer Equivalence:
(REN) 0.1 B
Dimensions:
1.5” H x 3.35” W x 5.3” L
FCC Information
This unit is designed to conform to federal regulations and complies with Part 68 of the FCC
rules. On the back of this equipment is a label that contains the FCC registration number and
ringer equivalence number (REN) for this equipment. Upon request, you may have to provide
the FCC registration number and the REN to your telephone company.
The ringer equivalence number (REN) is used to determine how many devices can be
connected to your telephone line. In most areas, the sum of the RENs on any one line should
not exceed 5. If too many devices are attached, your phones may not ring properly and other
devices on the line may not detect the ring signal.
In the most unlikely event that your unit causes significant problems on the telephone line, the
telephone company can disconnect your service. The telephone company will attempt to notify
you in advance and will advise you of your right to file a complaint with the FCC.