5
Fig. 3a CallerID.com Format
(DIP Switch #3 set OFF)
Line Number
Fig. 3b TCI Format
(DIP switch #3 set ON)
02 9/26 11:28 AM 770-263-7111 CALLERID.COM
Time
including
AM/PM
Indicator
Carriage Return
& Line Feed
2 Characters
11 Spaces
separate
these fields
Date Field
(Month, Day)
leading zeroes
are sent as spaces
NOTE: All fields
justified. 5 spaces separate each field except number and name fields.
right
Phone number field - 14 characters.
Unlike CallerID.com format, the phone
number is right justified.
Private & Out-of-Area sent in number field.
Name field - 15 characters, Right
justified. (Name sent in most areas).
Private & Out-of-Area codes are not
shown in name field.
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2
1 2 3 4 5 6 7
R
C
F
L
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
Phone Number field - 14 characters.
The text, “Private” or “Out-of-Area”
can be displayed in Number Field.
If Serial Output,
Carriage Return
and Line Feed
terminate string
Inbound/Outbound
and Start/End of
call Indicators.
(Always I and S
for Basic units)
Checksum
Indicator
G (Good)
or B (Bad)
Date Field
(Month, Day)
Leading zeroes
are displayed.
R
C
F
L
02 I S 0000 G A0 09/26 01:28 AM 770-263-7111 CALLERID.COM
Name field - 15 characters. Padded with
spaces if name less than 15 characters
(Caller ID Name not always available)
Time including
AM/PM Indicator.
Leading zeroes
are included.
Type of
ring and
# of rings.
(always
“A0”for
Basis units)
Duration
of call in
seconds
(always
zero for
Basic units)
Line
Number
Note: No dashes are inserted in phone number when unit set to UK-BT/ETSI type Caller ID signaling (DIP #4 up).