background image

Voltage Detection -

8 Channel Shunts to the Rear of Unit, Main shunt to Right

Current Detection

8 Channel Shunts to the Front of Unit, Main shunt to Left

Fig. B1 - Voltage and Current Detection Configuration (4 Line Model -PCB Version 6,7,or 8)

17

Callerid.com / 4-Line WC

V-

7

Callerid.com / 4-Line WC

V-

7

Unit is configured for
Voltage Detection when
all 9 shunts are
connected as shown.

Unit is configured for
Current Detection when
all 9 shunts are
connected as shown.

Summary of Contents for Whozz Calling Deluxe 2

Page 1: ...ID Whozz Calling Deluxe 2 4 8 Caller ID Interface Product Manual Caller com ID ID Revision 5 0 11 15 2015 SMT Versions CALLING WHOZZ 8 CALLING WHOZZ 4 CALLING WHOZZ 4 CALLING WHOZZ 4 CALLING WHOZZ 4...

Page 2: ...Whozz Calling 2 4 and 8 Line Deluxe Units Product Manual Revision 6 1 01 27 2020 SMT Versions...

Page 3: ...Appendix B On and Off Hook Detection Voltage vs Current 16 Appendix C RS232 Pin Outs 19 Appendix D Phone Line Compatibility 20 Appendix E Serial Loop Diagnostic Tool 21 Appendix F Explanation Of Start...

Page 4: ...up parameters see the phone number list used for call blocking and to reset the system The Send Data commands are used to set line numbers set the internal clock and enter phone numbers for call block...

Page 5: ...ive lines will flash dimly LEDs for inactive lines will flash dimly 9600 Baud N 8 1 9VDC Complies with FCC Part 68 FCC Reg No 2EWUSA 73088 ND N REN 0 5A 1 6B Jack USOC RJ11 Model WHOZZ CALLING Complie...

Page 6: ...e to the desktop phones through a phone switch if present 2 Wire RJ11 or 4 Wire RJ14 Phone Cord Connections Most modular phone cords contain 4 wires which can handle two phone lines 2 wires for each l...

Page 7: ...ould be inserted between each toggle so the unit it has enough time to write the entry to non volatile memory Setup Toggles This is a quick listing of the setup toggles A complete explanation of each...

Page 8: ...ne 1 through line 4 on a four line unit If n 5 unit reports L5 L8 on a four line unit Nnnnnnnnnnn CR Add phone number to memory for internal block pass feature Only available on select units Wnn CR No...

Page 9: ...E C c Leading character and dashes removed in phone number field Some applications need to detect a certain character in order to perform an operation When this toggle is set to c the unit places a ch...

Page 10: ...space and either a R Ring F ofF hook N oN hook or H Hook flash The date and time HH MM SS follow at the same offset as the date time field in the comprehensive format In the detail mode the time is de...

Page 11: ...e line number or the baud rate The time clock can be reset by using the Zmmddhhmm command see details below or by capturing a good Caller ID signal Data Entry Commands Discussion N000000770n CR Set st...

Page 12: ...ary format so that the time of the event can be determined exactly An example is shown below 01 R 11 07 07 43 52 Ringing on line 1 at 7 43 AM 01 F 11 07 17 45 04 Off Hook on line 1 at 5 45 PM 04 N 11...

Page 13: ...y are listed but if they over 15 characters truncation will occur Caller ID specifications allow for the delivery any characters or symbols Outbound Calls Figure 2b shows the format for outbound calls...

Page 14: ...ent after field Name Field 15 Characters Left Justified Carriage Return Line Feed are sent after field Type of ring and number of rings always zero at start of call Type of ring and number of rings al...

Page 15: ...om these numbers will receive a Private or Anonymous indication from their Caller ID device Private and Out of Area messages can occur in either the number or name fields if number and name service is...

Page 16: ...ty covers failures due only to defects in materials or workmanship occurring during normal use It does not cover damage which occurs in shipment failures which are caused by products not manufactured...

Page 17: ...in regions that use older CO equipment DTMF touch tones sent before the 1st ring NOTE Refer to the table in Fig A1 for more information on known formats in particular countries The standard factory s...

Page 18: ...t before 1st ring No time date no Caller ID name only Caller ID number sent Brazil Uruguay Guatemala and many other Central and South American countries Denmark Holland Iceland Sweden India Saudi Arab...

Page 19: ...DETECTION CIRCUITRY AND TELEPHONE LINES In order to sense the voltage on the phone line the unit s circuitry must draw a small amount of current from the phone line The current draw is very small 70 A...

Page 20: ...it Main shunt to Left Fig B1 Voltage and Current Detection Configuration 4 Line Model PCB Version 6 7 or 8 17 Callerid com 4 Line WC V 7 Callerid com 4 Line WC V 7 Unit is configured for Voltage Detec...

Page 21: ...Main shunt to Left Unit is configured for Voltage Detection when all 9 shunts are connected as shown Unit is configured for Current Detection when all 9 shunts are connected as shown 18 Callerid com...

Page 22: ...sides at 9 VDC Upon transmit the unit pulls this line to 9 VDC Other Whozz Calling units connected will detect this as a busy condition and will not transmit until the line returns to 9 VDC If your ap...

Page 23: ...may be compatible with Caller ID and outbound call monitoring or just outbound call monitoring only The unit senses On Off Hook by detecting the telephone line voltage levels If the voltage levels are...

Page 24: ...a CallerID com unit a Select the port number that it found the unit on b Use Default Baud Rate of 9600 c Make test calls on all phone lines connected to the unit d Raw data results are seen in top wi...

Page 25: ...ssion assumes a live phone line attached to a channel When a phone goes Off Hook the channel light goes off and pulses every second The light will come on during every touch tones dialed When the phon...

Page 26: ...hone lines the series pass through connection or the parallel branch off connection The series connection uses both input and output modular jacks on the unit The parallel connection uses only the inp...

Page 27: ...tive lines will flash dimly LEDs for inactive lines will flash dimly 9600 Baud N 8 1 9VDC Complies with FCC Part 68 FCC Reg No 2EWUSA 73088 ND N REN 0 5A 1 6B Jack USOC RJ11 Model WHOZZ CALLING Compli...

Page 28: ...er on the unit Connect one cord to the input of channel 1 If only the Line 1 light comes on you have a 2 wire RJ11 cord If both Line 1 and Line 2 lights come on you have a 4 wire RJ14 cord Continue ch...

Page 29: ...G2a Parallel Connection for 2 Wire RJ11 system Lines from Tel Co RJ21x Block Telephone Switch if present 4 Outside Lines modular or bare wire to telephone switch or directly to desktop phones 4 Modula...

Page 30: ...the switch first Fig G3a Series Connection for 2 Wire RJ11 system Lines from Tel Co RJ21x Block Telephone Switch if present 4 Outside Lines to Unit modular or bare wire 4 Lines to Telephone Switch or...

Page 31: ...5680 Oakbrook Parkway 150 Norcross GA 30071 800 240 4637 770 263 7111 Caller com ID ID...