9.0 Datasheet
MODEL
Units
AW629
AW829
HEAT TO POOL WATER
AMBIENT 10°C, WATER 24°C
kWh
7.0
9.9
12.
AMBIENT 20°C, WATER 24°C
kWh
9.20
12.5
15.
ELECTRICITY
ELECTRICAL SUPPLY 1 PHASE
TOTAL POWER CONSUMED
AMBIENT 10°C, WATER 24°C
kWh
1.8
2.3
3.1
AMBIENT 20°C, WATER 24°C
kWh
2.0
2.5
3.3
MIN SUPPLY CAPACITY (Max F.L.A.) 1 ph N:-
A
14.0
17.0
19.
RECOMMENDED SUPPLY FUSE 1 ph N:-
A
20.0
25.0
30.
WATER FLOWS ETC
POOL WATER FLOW RATE:-
L/min
115
115
16
POOL WATER PRESSURE DROP (@ Rated Flow):-
m hd
2.5
2.5
2.9
MAX WORKING PRESSURE POOL WATER:-
bar
3.5
3.5
3.5
POOL WATER CONNECTIONS:-
inches
CONDENSATE DRAIN CONNECTIONS:-
inches
COMPRESSOR
NOMINAL POWER CONSUMED
kWh
1.8
2.14
2.6
L.R.A. 1 ph N:-
A
66
63
10
R.L.A. 1 ph N:-
A
11.4
14
16.
SOFT START AMPS 1 ph N:-
A
18
18
35
MAIN FAN
AIR FLOW (Anemometer @ air on grille. Dry evaporator):-
m³/h
2200
3300
F.L.A. 1 ph N:-
A
0.8
0.8
0.9
GENERAL DATA
HERMETIC SYSTEM
GAS CHARGE R407c
kg
1.4
1.95
2.2
PHYSICAL DIMENSIONS
WIDTH (Unpacked):-
mm
1049
1227
107
DEPTH (Unpacked):-
mm
593
593
48
HEIGHT (Unpacked):-
mm
720
720
135
WEIGHT (Unpacked):-
kg
93
104
14
FOR ACCURATE APPLICATION SIZING CONSULT CALOREX HEAT PUMPS LTD
230V/~1N/ 50Hz
1 1/2" BSPM
3/4" DOMESTIC WASTE
NOTES
1) Weight and dimensions nett.
2) Performance design limitations: Ambient = 7ºC min 40ºC max, Water = 10ºC min, 40ºC max.
3) Pool water to have correct balance, pH 7.2-7.8, Free Chlorine 1.0 - 2.0ppm domestic, 3.0 - 6.0 commercial.
4) Allow 500mm clearance to service panels.
5) Calorex reserve the right to change or modify models without prior notice.
6) R407c Global warming potential (GWP) 1700.
1mm WG = 9.8 Pa
1mhd = 1.4 psi
1l/min = 0.22gall/min
HEAT PUMPS FOR OUTDOOR POOLS SUMMER SEASON (AL/BL)