56
1002594 ISSUE 1 M172 VARIHEAT
VARIHEAT AW SYSTEM OWNER INSTALLATION MANUAL
5.0 VARIHEAT DATA SHEET
Specifications
Units
AW600A
AW600B
AW900A
AW900B
AW1200A
AW1200B
AW1500B
Dehumidification
Heat pump dehumidification 30°C/60% RH
Total at 18°C dew point (summer) - if fresh air option fitted
Total at 7°C dew point (winter) - if fresh air option fitted
L/h
L/h
L/h
4.6
5.2
6.5
6.5
7.3
9.0
8.5
9.5
11.7
10.5
11.3
13.9
Heat to air
Heat pump heat recovery - Mode A (priority to water)
Heat pump heat recovery - Mode B (priority to air)
Standard LPHW at 80°C flow
Upgraded LPHW at 55°C flow
Total - std. LPHW + Mode A/Mode B heat recovery
kW
kW
kW
kW
kW
0
5.1
11.0
9.4
11.0/14.0
0
7.1
13.5
11.5
13.5/18.6
0
10.0
24.0
20.4
24.0/30.0
0
14.0
28.0
23.8
28.0/36.0
Heat to pool water
Heat pump heat recovery - Mode A (priority to water)
Heat pump heat recovery - Mode B (priority to air)
LPHW @ 80°C
LPHW @ 55°C
Total - std. LPHW + Mode A/Mode B heat recovery
Flow rate pool water ± 10%
Pressure drop at rated flow
Maximum working pressure
kW
kW
kW
kW
kW
L/min
m/kPa
bar
5.5
0
18.0
9.0
23.5/18.0
30
3.5/34.3
3.5
7.4
0
30.0
15.0
37.4/30.0
32
3.5/34.3
3.5
10.0
0
30.0
15.0
40.0/30.0
33
3.5/34.3
3.5
12.5
0
40.0
20.0
52.5/40.0
40
3.5/34.3
3.5
LPHW data
Recommended min. boiler capacity (standard LPHW at 80°C)
Recommended min. boiler capacity (upgraded LPHW at 55°C)
Flow rate - standard LPHW
Flow rate - upgraded LPHW
Pressure drop at rated flow rate - standard LPHW
Pressure drop at rated flow rate - upgraded LPHW
LPHW system volume
Maximum working pressure
kW
kW
L/min
L/min
m/kPa
m/kPa
L
bar
29
19
25
32
6.3/61.7
6.3/61.7
1.6
6
44
27
32
44
6.3/61.7
6.3/61.7
1.6
6
54
36
42
64
6.3/61.7
4.5/44.1
3.2
6
68
44
52
74
6.3/61.7
4.9/48.0
3.2
6
Electrical data
Typical high pressure system with constant flow fan
Typical low pressure system with constant flow fan
Minimum supply capacity (FLA) 230V/1N/50Hz
Minimum supply capacity (FLA) 400V/3N/50Hz
Maximum supply fuse 230V/1N/50Hz
Maximum supply fuse 400V/3N/50Hz
kW
kW
A
A
A
A
2.1
1.8
17.2
11.6
25
16
2.8
2.4
22.5
13.2
32
16
3.6
3.1
29
17.8
42
25
5.1
4.7
-
12
-
16
Main fan data - constant flow fans
Design air flow (anemometer @ air on filter, wet evaporator) ± 10%
Maximum external static pressure standard LPHW
Maximum external static pressure upgraded LPHW
Design running amps - 230V/1N fans
Design running amps - 400V/3N fans
FLA - 230V/1N fans
FLA - 400V/3N fans
m³/h
Pa
Pa
A
A
A
A
2000
330
320
3.8
-
7.6
-
2500
220
208
4.7
-
7.6
-
3500
290
178
9.3
-
9.3
-
4300
350
320
-
1.4
-
4.0
Optional fresh air module
Air flow
Maximum external static pressure
Heat required for fresh air at -5°C
m³/h
Pa
m³/h/kW
0-900
100
150/1.8
0-900
100
200/2.3
0-900
100
250/2.9
0-900
100
300/3.5
Optional electric air heater module - (separate power supply)
Nominal power (two options per model)
Minimum supply capacity (FLA) 230V/1N/50Hz
Minimum supply capacity (FLA) 400V/3N/50Hz
Maximum supply fuse 230V/1N/50Hz
Maximum supply fuse 400V/3N/50Hz
kW
A
A
A
A
6 or 12
30 or 60
9 or 18
32 or 63
10 or 20
6 or 12
30 or 60
9 or 18
32 or 63
10 or 20
12 or 18
60 or -
18 or 27
63 or -
20 or 30
12 or 18
60 or -
18 or 27
63 or -
20 or 30
Compressor data
Nominal power consumed
Nominal RLA - 230V/1N/50Hz
Starting current 230V/1N/50Hz
Starting current 230V/1N/50Hz (with soft start)
Nominal RLA 400V-3N-50Hz
Starting current 400V/3N/50Hz
Starting current 400V/3N/50Hz (with soft start)
kW
A
A
A
A
A
A
1.5
8.0
55
26
3.2
30
14
2.0
12.4
76
31
4.7
42
16
2.5
16.6
100
34
7.3
48
17
3.4
-
-
-
10.0
48
25
General data
Hermetic refrigeration system
- gas charge (R407C)
Typical weight - unpacked
kg
kg
1.8
170
2.0
171
2.9
230
3.0
240