background image

6

Submersible sewage and

drainage pumps

GX 40, GM 50

OPERATING INSTRUCTIONS

1. Pump designation

See designation on the pump name-plate or on

the bar-code label.

Meaning of the designations:

GX 40

= Stainless steel pump with G 1

1

/

2

ISO 228 (DN 40) delivery connection.

GM 50

= Cast iron pump with G 2 ISO 228

(DN 50) delivery connection.

GM 50-65

= Cast iron pump with (DN 65)

flanged delivery connection.

C

= With two- (

GXC

) or single-passage

(

GMC

) impeller.

V

= With free-flow (vortex) impeller.

M

= With single-phase motor (without

indication = with three-phase motor).

2. Operating conditions

Standard construction

- For clean and dirty water, also containing solids

with maximum size: 

35 mm for 

GX 40

;

45 mm for 

GMC ..

; 50 mm for

GMV ..

..

With a high solid content or with filamentous par

ticles use only the free-flow (vortex) 

GXV

and

GMV

construction.

- Maximum liquid temperature: 35 °C.

- Maximum liquid density: 1100 kg/m

3

.

- Minimum dimensions of installation pit: 

0.55x0.55m; depth 0.5 m.

- Minimum immersion depth: 

250 mm for 

GX 40

;

180 mm for 

GM 50

.

- Maximum submersion depth:

GX 40

= 5 m;

GM 50

= 10 m (with suitable cable length).

- Maximum starts/hour: 30 at regular intervals.

Sound pressure at minimum immersion depth:

< 70 dB (A).

Noise disappears when the pump is submersed.

Do not use in garden ponds, tanks or

swimming pools when people are in the

water.

The Pump cannot be used in

explosive or flammable environments.

3. Installation

The internal diameter of the delivery pipe must never be

smaller than the diameter of the pump connection port:

G 1

1

/

2

(DN 40) for 

GX 40

G 2 (DN 50) for 

GM 50

;

(DN 65) for 

GM 50-65

.

The pump must be lifted and transported using

the handle fitted for this purpose and not pulled

by the electrical power cable.

Place the pump, with vertical axis, at the bottom

of the pit or at the site of installation.

3.1. Stationary installation

For stationary installation fit a check valve against

back flow in the delivery pipe.

Provide for the possibility of removing the pump

without having to drain the entire system (if

necessary, fit a gate valve and a union coupling).

With the pump in the resting position secure the

delivery pipe to a rest, suitable for its length and

weight.

If slime deposits are expected to form at the

bottom of the installation pit, a support must be

provided to keep the pump raised.

3.2. Transportable installation

A

safety rope or chain

of non-perishable material

should always be used to secure the pump.

When a plastic or flexible delivery pipe is used,

the safety rope or chain should be utilized for

lowering, securing and raising the pump.

3.93

.037

/3

3.93.037/3

GX

 = 250

GM

 = 180

GX

 = 450

GM

 = 500

3.93

.037

/3

3.93.037/3

GX

 = 250

GM

 = 180

GX

 = 450

GM

 = 500

On

Off

Reviews: