POWER/ENVIRONMENTAL SPECIFICATIONS
The console has two IEC AC power inlets feeding two sets of internal power distribution. Although the console will
operate with one inlet supply we recommend both inlets are powered. This will ensure continued operation should a PSU
or AC source fail. The operating AC supply voltage is 100 V - 240 V +/-10%.
Theaveragehalf-cycler.m.sinrushcurrentperinlet:
• Oninitialswitch-on<5A
• After5sinterruption<10A
CONTROL UNIT
RP1
240V Operation
115V Operation
100V Operation
Supply Current
0.48A
0.86A
0.98A
Power Factor
0.68
0.79
0.80
Power Dissipation (Heat) -
78.3W
78.4W
78.4W
Cooling
TheRP1iscooledbyaquietouttakefanontherearoftheunit.
Theairintakeisonthesideventsoftheunit.
Atleast50mm(2’)clearanceshouldbemaintainedforthesevents.
Ifthesidesareobstructed,thetrimswillpullairfrombelowandrear.
Operating Ambient Air
Temperature
0°C-40°C
Note that RP1 is a self contained unit and the processing core is built into the unit.
Summary of Contents for RP1
Page 1: ...calrec com Remote Production System REMOTE PRODUCTION RP1 SYSTEM MANUAL V1 1...
Page 6: ...6 RP1 Remote Production System...
Page 7: ...calrec com RP1 INFORMATION...
Page 12: ...12 RP1 Remote Production System...
Page 13: ...calrec com RP1 GETTING STARTED...
Page 17: ...calrec com RP1 INSTALLATION...
Page 38: ...38 RP1 Remote Production System...
Page 39: ...calrec com RP1 SYSTEM SOFTWARE UPDATES...
Page 41: ...calrec com RP1 CONFIGURING LAN PORTS CONNECTIVITY...
Page 48: ...48 RP1 Remote Production System...
Page 49: ...calrec com RP1 SETUP VIA CALREC ASSIST...
Page 54: ...54 RP1 Remote Production System...
Page 55: ...calrec com RP1 SHOWS...
Page 61: ...calrec com RP1 SETUP PATHS FOR ACTIVE SHOW...
Page 73: ...calrec com RP1 ACCESS PROCESSING...
Page 81: ...calrec com RP1 ACCESS ROUTING...
Page 84: ...84 RP1 Remote Production System...
Page 85: ...calrec com RP1 BUSES OUTPUTS...
Page 87: ...calrec com RP1 MONITORING...
Page 89: ...calrec com RP1 SYSTEM STATUS...
Page 91: ...calrec com RP1 EXTERNAL METERING DISPLAY...
Page 93: ...calrec com RP1 SETUP REMOTE NETWORKS ON HOST H2O...
Page 97: ...calrec com RP1 OPERATION VIA HOST CONSOLE...
Page 115: ...calrec com RP1 SPECIFICATIONS...