2011 Portable Spa
LTR20111001, Rev. B
Operating
Your Spa
www.calspas.com
18
The first filter cycle is automatically activated at
•
8:00 AM and operates the pump until 10:00 AM.
The “FILTER 1” indicator icon will light when filter
1 is running.
The second filter cycle is automatically activated
•
at 8:00 PM and operates the pump until 10:00 PM.
The “FILTER 2” indicator icon will light when filter
2 is running.
The pump and the ozone generator will run during
filtration. At the start of each filter cycle, the blower
will run on highest speed for 30 seconds to clean out
the air channels. The lowest speed of pump 2 and
pump 3 will run for five minutes. In the event of power
loss or shut down, the time of day will need to be
reset for filter cycles to run according to your desired
programming.
Clean-up Cycle
When the pump or blower is turned on by a button
press, a clean-up cycle begins 30 minutes after the
pump or blower is turned off or times out. The pump
and the ozone generator will run for one hour.
Ozone (optional)
On most systems, the ozone generator (if installed)
runs during filter cycles (except when pump 1 is
operating at high speed on a non-circulation system)
and during clean-up cycles. On some systems, the
ozone generator operates whenever the pump runs.
If your system is configured with the optional ozone
disable feature, the ozone generator will turn off for
one hour any time a function button (JETS 1, JETS 2,
OPTION etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 6.7˚C
within the heater, the pump automatically activates
to provide freeze protection. The equipment stays
on until four minutes after the sensors detect that
the spa temperature has risen to 7.2˚C or higher. In
colder climates, an optional additional freeze sensor
may be added to protect against freeze conditions that
may not be sensed by the standard sensors. Auxiliary
freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch and
without a four minute delay in turnoff.
Periodic Reminder Messages
Press the “Mode” button to reset a displayed reminder)
Message Frequency
Action Required
rPH
Every 7 days
Test and adjust chemical levels per manufacturer’s instructions.
rSA
Every 7 days
Test and adjust chemical levels per manufacturer’s instructions.
rCL
Every 30 days
Remove, clean, and reinstall filter per manufacturer’s instructions.
rtg
Every 30 days
Test & reset GFCI per manufacturer’s instructions. Drain and refill spa per
manufacturer’s instructions.
rdr
Every 90 days
Drain and refill spa per manufacturer’s instructions.
RCO
Every 180 days
Clean and condition spa cover
RCH
Every 365 days
Install New Bio-Clean™ Filter
Diagnostic Messages
Message
Meaning
Action Required
No message on display. Power has been
cut off to the spa.
The control panel will be disabled until power
returns.
OHH
“Overheat” - The spa has shut down.
One of the sensors has detected 47.7˚C
at the heater.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. Once the heater has cooled,
reset by pushing any button. If spa does not reset,
shut off the power to the spa and call your dealer or
service organization.