background image

Portable Spa Pre-Delivery Guide

LTR50001024, Rev. J

Locating 

Your Spa

www.calspas.com

7

Check the Dimensions of Your New Spa

The  specification  chart  on 

page  13  lists  your  spa’s 

model and its dimension as it sits on the delivery cart. 

During delivery, the spa must remain on the delivery 

cart at all times. Compare the dimensions to the width 

of  the  gates,  sidewalks,  and  doorways  along  the 

delivery route. It may be necessary for you to remove a 

gate or partially remove a fence in order to provide an 

unobstructed passageway to the installation location.

Plan the Delivery Route

Consider  the  following  when  planning  your  delivery 

route:

Check the width of gates, doors and sidewalks to 

• 

make sure your spa will pass through unobstructed. 

You may have to remove a gate or part of a fence 

to allow for adequate width clearance.
Are there low roof eaves, overhanging branches 

• 

or  rain  gutters  that  could  be  an  obstruction  to 

overhead clearance?
8’ spas need at least 42 wide gate and 9’ height 

• 

clearance.

If the delivery route will require a 90º turn, check 

• 

the measurements at the turn to ensure the spa 

will fit.

Are  there  protruding  gas  meters,  water  meters 

• 

or  A/C  units  on  your  home  which  will  cause 

obstructions  along  the  delivery  path  to  your 

yard?
Are there stairs in your delivery route? If so, you 

• 

must consult your Cal Spas dealer prior to delivery 

to make adequate preparations.

Special Circumstances

The use of a crane for delivery and installation may 

become  necessary  if  you  are  unable  to  provide  an 

adequate delivery route. It is used primarily to avoid 

injury to your spa, your property or to delivery personnel. 

Your Cal Spas dealer may be able to assist you with 

the  arrangements.  If  your  spa  delivery  requires  the 

use  of  a  crane,  the  cost  of  a  crane  is  generally  not 

included in the standard delivery service.

Getting the Spa Into Your Yard

Summary of Contents for Cal Spas Home Resort

Page 1: ...LTR50001024 Rev J 1 2 13...

Page 2: ...a CA 91766 Toll Free 1 800 CAL SPAS Fax 1 909 629 3890 This guide is intended for owners of Cal Spas portable spas sold in the United States and Canada If you have an in ground spa you will need the C...

Page 3: ...m around it for activity If you will use it for relaxation and therapy you ll probably want to create a specific mood around it Plan for your environment If you live in a region where it snows in the...

Page 4: ...ntion to the flooring beneath it Choose flooring that will not be damaged or stained If you are installing your spa on an elevated wood deck or other structure it is highly recommended that you consul...

Page 5: ...wish provided the spa is on a 3 4 30 cm concrete slab See the figure below Other spa models require access to the sides or rear should if they ever need service or repair See the figure on page 4 If...

Page 6: ...imum distance from edge of concrete slab Not to scale Top View of Spa Frame on Concrete Slab Equipment Pack Platform Minimum of 3 feet clearance to provide access to equipment area These spas require...

Page 7: ...f the spa See the drawing on the next page We do not recommend the stub up extending higher than 4 above the concrete slab Spas equipped with a pump in the left corner will need to have a hole drilled...

Page 8: ...le Front of Spa Equipment Pack Platform Location of electrical stub up 8 13 Not to scale Top View of F1770 Swim Spa Frame on Concrete Slab Swim Pump Platform 12 12 Location of electrical stub up Acces...

Page 9: ...ance Are there low roof eaves overhanging branches or rain gutters that could be an obstruction to overhead clearance 8 spas need at least 42 wide gate and 9 height clearance If the delivery route wil...

Page 10: ...uns over 85 feet must increase wire gauge to the next lower number For example A normal 50 amp GFCI with four 6 AWG Copper wires run over 85 feet would require you to go to four 4 AWG copper wires Ele...

Page 11: ...wires Service 3 spa side One 40 amp GFCI Four 8 AWG copper wires One 40 amp GFCI Four 8 AWG copper wires Electrical Installation for 11 kW Heater This applies to Fitness spas with the 11 kW heater onl...

Page 12: ...Portable Spa Pre Delivery Guide LTR50001024 Rev J Electrical Installation www calspas com 10 GFCI Wiring Diagram...

Page 13: ...isplayed in Celsius No circ pump Pump 1 is two speed A9 Circ pump acts like Pump 1 low speed filter cycle polling Pump 1 is one speed See table at right A10 See table at right Note Arrow indicates fac...

Page 14: ...onger than 15 ft 4 6 m and must be plugged into a dedicated 15 amp GFCI connection Do not use extension cords Always use a weatherproof covered receptacle Receptacle shall be located not less than 5 f...

Page 15: ...340 A750B 84 84 35 425 800 4340 A830L 93 93 35 450 900 4650 A830B 93 93 35 450 900 4650 A850L 93 93 35 450 900 4650 A850B 93 93 35 450 900 4650 Connect Series Model Width inches Length inches Height i...

Page 16: ...8 39 5 900 1250 8750 Resort Series Model Width inches Length inches Height inches Capacity gallons Dry Weight pounds Filled Weight pounds R862 93 93 35 450 900 4650 R890B 90 90 35 450 900 4650 R890L 9...

Page 17: ...h cm Height cm Capacity liters Dry Weight kg Filled Weight kg A511R 198 Round 91 1134 159 1293 A621T 183 183 89 491 272 764 A730B 213 213 89 1607 363 1970 A730L 213 213 89 1607 363 1970 A750L 213 213...

Page 18: ...0 100 3024 545 3569 Escape Series Model Width cm Length cm Height cm Capacity liters Dry Weight kg Filled Weight kg ES734B 213 213 100 1607 363 1970 ES734L 213 213 100 1607 363 1970 ES750B 213 213 100...

Page 19: ...ss Series Model Width cm Length cm Height cm Capacity liters Dry Weight kg Filled Weight kg F1239 236 424 130 7560 726 8286 F1418 II 236 358 130 5670 726 6396 F1439 II 236 434 130 6804 817 7621 F1640...

Page 20: ...LTR50001024 Rev J 1 2 13 LMS Customer Service Department 1462 East Ninth Street Pomona CA 91766 Toll Free 1 800 CAL SPAS Fax 1 909 629 3890 www calspas com...

Reviews: