2013 Portable Spa
LTR20131000, Rev. E
Operating
Your Spa
www.calspas.com
13
Operating Your Spa
VS300, VS513Z, and 5100 Control Operation
This section shows you how to use these control boxes:
VS300
5100 (single voltage)
VS513Z
5100 (dual voltage)
If you are unsure which control box your spa has, contact your spa dealer.
These instructions will describe features and options that your particular spa may not be equipped with.
Used for single pump systems
Used for two and three pump systems
When fi rst powered up, your spa will perform a self-
diagnostic check and go into priming mode. When
the control panel displays
PR
, do the following:
Press the
1.
JETS
button to turn
on the pump and let it run for
10 seconds. The pump should be
running in low speed.
Press the
2.
JETS
buttons again and
let the pump run in high speed for 10 seconds.
Press the
3.
JETS
button again to turn off the pump.
The pump should be left in the off position for 10
to 15 seconds.
Repeat steps 1 through 3 until water is fl owing
4.
through all the jets and all air is removed from
the plumbing.
When the spa has fi nished priming, the heater will
be activated and the water temperature will be
maintained in standard mode. The spa will heat to
100°F (37.5°C) at start up until the set temperature
is changed as described below.
Initial Start up
Summary of Contents for F1239
Page 1: ...LTR20131000 Rev E 9 18 13 ...