2013 Portable Spa
LTR20131000, Rev. E
Operating
Your Spa
www.calspas.com
15
VS300, VS513Z, and 5100 (single voltage)
systems
A steady light means that the spa is operating at
220V.
A
rapidly flashing light
means that the heater
is reading the water temperature. When the
temperature has been determined, the heater
light will stop flashing. You will frequently see the
heater light flashing rapidly while it is also steady
or slowly blinking.
Heating Modes
The spa can be set to operate in three different
heating modes:
Standard:
•
When the spa is powered up, it will
automatically start in Standard heating mode.
In Standard mode, the heating system will
automatically maintain the set spa temperature.
STD
or
ST
will light briefly on the main display.
Economy:
•
In Economy mode, the heating
system will only activate during filtration times
and will heat the water to the set temperature.
Ecn
or
Ec
will display solid if temperature is not
current and will alternate with spa temperature
if measured temperature is current.
Sleep:
•
In Sleep mode, the heating system
will only activate the heater during the filtering
cycles but will only heat the water to within 20°F
(10°C) of the set temperature. Like Economy
mode,
SLP
or
SL
will display solid when
temperature is not current and will alternate
with actual temperature when it is current.
NOTE: Displayed temperature will only be current
after the pump has been running for at least two
minutes.
Switching Heating Modes
Press
•
Temp
button followed by
the
Light
button.
Press the same sequence to
•
switch to the next mode.
Temperature Adjustment
(Range 80°F to 104°F, 26°C to 40°C)
The electronic control panel displays the actual
water temperature in degrees Fahrenheit. The
displayed temperature will only be current after the
pump has been running for at least two minutes.
To set the temperature on single pump spas
Press the
•
Temp
button. The temperature
setting will flash.
While the display is flashing, each
•
time you press
Temp
button, the
set temperature will change up or
down one degree.
If the desired temperature is opposite of the
•
direction each press of the button is making,
release button, allow display to stop flashing
and then press
Temp
button to change
temperature the other direction.
To set the temperature on two or three pump
spas
Press the
•
Temp UP
or
Temp
DOWN
button. The temperature
setting will flash.
While the display is flashing, each
•
time you press the
Temp UP
or
Temp DOWN
button, the set
temperature will change up or
down one degree.
5100 (dual voltage) system ONLY
A steady light means that the spa is operating at
220V.
A slowly blinking light means that the spa is
operating at 120V.
A
rapidly flashing light
means that the heater
is reading the water temperature. When the
temperature has been determined, the heater
light will stop flashing. You will frequently see the
heater light flashing rapidly while it is also steady
or slowly blinking.
Heater Light
The heater light will turn on whenever the heater is operating. It will appear different ways when the
spa is operating:
Summary of Contents for F1418
Page 1: ...LTR20131000 Rev E 9 18 13...