2013 Portable Spa
LTR20131000, Rev. E
Operating
Your Spa
www.calspas.com
20
Periodic Reminder Messages
Applies to 5100DV, 6200DV, 6300DV, and 9800 control systems. Press the “Mode” button to reset a displayed
reminder.
Message
Frequency
Action Required
rPH
Every 7 days
Test and adjust chemical levels per manufacturer’s instructions.
rSA
Every 7 days
Test and adjust chemical levels per manufacturer’s instructions.
rCL
Every 30 days
Remove, clean, and reinstall filter per manufacturer’s instructions.
rtg
Every 30 days
Test and reset GFCI per manufacturer’s instructions. Drain and refill
spa per manufacturer’s instructions.
rdr
Every 90 days
Drain and refill spa per manufacturer’s instructions.
rCO
Every 180 days
Clean and condition spa cover.
rCH
Every 365 days
Install a new filter.
Diagnostic Messages
Applies to 5100DV, 6200DV, 6300DV, and 9800 control systems.
Message
Meaning
Action Required
No message
on display
1) Spa temperature is unknown.
1) After pump has been running for 2 minutes
temperature will be displayed.
2) Spa is in Economy or Sleep
mode.
2) In Economy or Sleep mode, the pump may be off
for hours outside a filter cycle. If you wish to see the
current spa temperature, either switch to Standard
mode or turn Jets 1 on for at least two minutes.
3) Power has been cut off to the
spa.
3) The control panel will be disabled until power
returns. Spa settings and time of day will be
preserved for 30 days with a battery back-up.
BUF
Internal problem detected.
Repair required. Contact your dealer or service
organization.
dr
Insufficient water detected in
heater. Spa will be shut down for
15 minutes.
Check water level in spa. Refill if necessary. Make sure
pumps have been primed and filter cartridges are
clean. Press any button to reset or wait 15 minutes
and spa will automatically reset. If message spa does
not reset, call your dealer or service organization.
dry
dY
Insufficient water detected in
heater. Spa is shut down.
(Displays on third occurrence of dr
message.)
Follow directions for dr message and press any button
to reset spa. Spa will not automatically reset when dry
or dY is displayed.
Ec
Indicates heater is in Economy
Mode.
None.
--F or --C
Temperature unknown
After the pump has been running for two minutes, the
temperature will be displayed.
HL
HFL
A difference in readings between
temperature sensors has been
detected indicating a possible water
flow problem.
Make sure spa is filled to proper level and that
pumps are primed and filter cartridges are clean. If
message does not reset, call your dealer or service
organization.
Summary of Contents for F1418
Page 1: ...LTR20131000 Rev E 9 18 13...