background image

2018 Platinum Series Spas

LTR20181010, Rev. H

W

ater Clarity

www.calspas.com

31

The bromine generator automatically generates 

and releases free bromine into the spa water. You 

will still need to test for bromine and occasionally 

adjust it to return the bromine level to the 

baseline.

Start-up/Operating Instructions

Be certain that you start with a clean spa. It should 

be free of contaminants and other residues that can 

accumulate on the sides and/or around the jets. It 

is also important to only use spa cleaning products 

that have 

no phosphates 

or phosphonic acids 

since phosphates will deplete free bromine and are 

super-food for algae.  Always start your spa with a 

clean filter before filling with water.
If  the  water  source  is  “well  water”  or  a  non-

municipal water source, have your water tested 

for Total Dissolved Solids (TDS) and metals. Water 

with high TDS is likely to have higher metal content 

and will need a metal remover to decrease the 

metals and ensure a successful start. This test 

can be done by your local spa dealer. The ideal 

range for your start-up TDS is between 50 and  

200 ppm - mg/L. If TDS from your source water 

is above 500 ppm, a metal remover is strongly 

recommended.    
DO NOT FILL THE SPA WITH SOFT WATER.
1. 

Using  your  PURE  FILL  Spa  Pre-Filter,  fill  your 

spa with water to the recommended level (six 

inches below the lip of the spa) and DO NOT 

FILL WITH WATER FROM A “RESIDENTIAL 

WATER SOFTENER.”

2.  Before starting the system, balance your water 

chemistry to ensure a successful start up. Ideal 

ranges are as follows:

Ideal Range

Minimum

Maximum

pH

7.2

7.6

Total alkalinity

80 ppm

120 ppm

Calcium hardness

150 ppm

250 ppm

Phosphates

0 ppb

30 ppb

Use the phosphate test kit included with your 

system.  Bromide  residuals  will  be  significantly 

reduced if phosphate levels are high. If phosphates 

are detected, purchase a phosphate remover and 

follow the directions accordingly. 

Any

 phosphates in 

your spa will reduce bromine levels.
3. 

Determine the level of “NaBr” (Sodium Bromide) 

required for your spa size. NaBr should be added 

at a rate of 1.2 lbs per 100 gallons or approximately 

1300-1500 ppm.

Example:

  For a 500 gallon spa add 

approximately 6 lbs of NaBr. 

1 .2 lbs x (5) 500 

gallons = 6lbs NaBr .

 

4. 

Turn the jets on high speed. Sprinkle the NaBr 

across the surface of the water to evenly 

distribute the NaBr in the spa and circulate for 

30 minutes.

5.  Test the Sodium Bromide concentration with the 

Tru-Blu NaBr test kit. The correct amount of 

NaBr will secure a reading of between 1300-

1500 ppm.

6. 

Adjust the filtration time to circulate for 8 hours 

every 24 hours on a 2 speed pump.

7. 

For a spa between 300-500 gallons, start at a 

power level of “6” and then press the “boost” 

feature. This will accelerate the production of 

bromine for 8 hours.  Wait for proper bromine 

levels before entering the spa.

8.  Always keep your bromine level between 

3-5ppm. Test the bromine level after 24 hours 

and adjust the power setting accordingly.  An 

occasional heavier bather load may require the 

“boost” feature.

Bromine Generator

Summary of Contents for Platinum Plus

Page 1: ...LTR20181010 Rev H 8 6 18...

Page 2: ...lectrical Power Efficiency 23 Jets 23 LED Lighting 23 Diverter Knobs 24 Air Venturis 24 Waterfalls 24 ATS Plus Therapy System 25 Aquatic Air TherapyTM AAT 26 Water Clarity The Key to Clear Water 27 Te...

Page 3: ...duce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level 3 F to 6 F above the normal body temperature of 98 6 F or 2 C to 4 C above 37 C While hyperthermia has m...

Page 4: ...e when entering or exiting the spa or hot tub WARNING Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning WARNING Do not use a spa o...

Page 5: ...ou will use it for relaxation and therapy you will probably want to create a specific mood around it If you live in a region where it snows in the winter or rains frequently place the spa near a house...

Page 6: ...he only acceptable electrical wiring procedure Spas wired in any other way will void your warranty and may result in serious injury When installed in the United States the electrical wiring of this sp...

Page 7: ...e operating 1 Press the TEST button on the GFCI The GFCI will trip and the spa will shut off 2 Reset the GFCI breaker by switching the breaker to the full OFF position wait a moment then turn the brea...

Page 8: ...2018 Platinum Series Spas LTR20181010 Rev H Preparing for Your New Portable Spa www calspas com 6 Wiring Diagram for Europe...

Page 9: ...ir into the filtration system which can cause the pump to fail to prime Never try to pull the filter cartridge while the spa is running in low or high speed i e any speed Make sure unions in the equip...

Page 10: ...it in Do not over torque the cartridge during installation just hand tighten gently 7 Adjust water chemistry Test and adjust the water chemistry See the section on page 27 for instructions on water cl...

Page 11: ...can help you Sometimes air can become trapped in the pump while filling the spa You will know this has happened when after you have filled and started the spa the pump does not seem to function You w...

Page 12: ...e spa and locate the pump 3 Close the gate valve on the discharge side of the pump if your spa is installed with one 4 Turn the bleeder valve counter clockwise with a small pair of pliers until the ai...

Page 13: ...Spas LTR20181010 Rev H Operating Your Spa www calspas com 11 Operating Your Spa spaTouch 2 Icon Driven Control Panel Changing Languages for the Display 1 Touch the Settings Icon at the lower right po...

Page 14: ...Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 12 2 Touch the Right Arrow Icon at the lower right portion of the screen It takes you to the next page 3 Touch the Language I...

Page 15: ...20181010 Rev H Operating Your Spa www calspas com 13 4 As an example touch the Spanish option as shown below 5 Next touch the Save Icon to confirm this selection 6 and now for example the spaTouch scr...

Page 16: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 14 The Main Screen Home...

Page 17: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 15...

Page 18: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 16...

Page 19: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 17...

Page 20: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 18...

Page 21: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 19...

Page 22: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 20...

Page 23: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 21...

Page 24: ...tion is made You can then connect to the spa s wi fi module Range Worldwide Range limit Limited to 3G 4G hotspot availability Through home network with no internet access Range About 50 feet Range lim...

Page 25: ...et See example shown below Neck jets adjust in the opposite directions counter clockwise to increase clockwise to decrease LED Lighting Press the LIGHT button on the topside control panel to turn the...

Page 26: ...he amount of water flow through the other section of jets rotate the handle to the right clockwise Air Venturis Air venturis are the 1 knobs located around the top of your spa Each one will let you ad...

Page 27: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 25 ATS Plus Therapy System...

Page 28: ...2018 Platinum Series Spas LTR20181010 Rev H Operating Your Spa www calspas com 26 Aquatic Air TherapyTM AAT...

Page 29: ...sed dolumsandit at Rat consequi tinim ilisi bla feuis euguerc ilisi Em verit iliqui endiam nulluptat lamcore minibh elestio num sandip eraesectem diatio ercing ea cortis delissed dunt utpatisi Ut vel...

Page 30: ...ill tend to be too high and may be difficult to bring down High TA can be corrected by adding an alkalinity decreaser When the TA is balanced it normally remains stable although adding water with high...

Page 31: ...sanitizer only use granulated chlorine not liquid chlorine Once a week check the chlorine level using either a test strip or a reagent kit See the table on the following page for the ideal range Add...

Page 32: ...once a month and replace it once a year or as necessary It is extremely important that you never run the spa without a filter There is a possibility that debris may be sucked into the plumbing throug...

Page 33: ...ATER SOFTENER 2 Before starting the system balance your water chemistry to ensure a successful start up Ideal ranges are as follows Ideal Range Minimum Maximum pH 7 2 7 6 Total alkalinity 80 ppm 120 p...

Page 34: ...you have a bromine reading that is too high or too low adjust the DECREASE INCREASE control accordingly Depending on the amount usage circulation time and type of spa each spa owner s setting will be...

Page 35: ...Every two to four months Change the spa water How often you change the water depends on how much you use the spa When you change the water you will need to Clean and polish the acrylic surface see pa...

Page 36: ...r to remove the scum and refill the spa Algae Growth High pH Low sanitizer level Shock spa with sanitizer and adjust pH Shock spa with sanitizer and maintain sanitizer level Eye Irritation Low pH Low...

Page 37: ...s ultraviolet rays You are required to keep the spa covered to maintain warranty coverage Covering your spa helps prevent children from drowning in the spa See the manual enclosed with your cover for...

Page 38: ...ilters Draining Your Portable Spa 3 Connect valve to a garden hose Attach a garden hose to the hose bib fixture Place the other end of the garden hose where you would like the water to drain 1 Locate...

Page 39: ...uum 5 Open the bleeder valves on the pumps 6 For spas with the UV lamp chamber mounted flat on the equipment floor Loosen the quartz tube nut at the top of the UV lamp chamber and pull up the quartz t...

Page 40: ...constant punishment your spa cover and pillows receive you should protect them by applying a vinyl and leather cleaner as part of your monthly maintenance plan Use a product that is specifically desi...

Page 41: ...5 D x 5 5 L Velocity Roto Blue Jet Symbol 5R Part PLU29950 081 400 Size 5 D x 5 5 L Appendix Snap in SQR Jet Inserts Velocity Roto LED Jet Symbol 5R Part PLU29950 081 100 Size 5 D x 5 5 L Velocity Di...

Page 42: ...71 100 Size 5 D x 5 5 L Velocity Tornado WP Blue Jet Symbol 5T Part PLU29950 501 400 Size 5 D x 5 5 L Snap in SQR Jet Inserts Velocity Tornado WP LED Jet Symbol 5T Part PLU29950 501 100 Size 5 D x 5 5...

Page 43: ...940 112 100 Size 4 D x 4 5 L Velocity Roto Blue Jet Symbol 4R Part PLU29940 122 400 Size 4 D x 4 5 L Snap in SQR Jet Inserts Velocity Roto LED Jet Symbol 4R Part PLU29940 122 100 Size 4 D x 4 5 L Velo...

Page 44: ...9930 142 100 Size 3 D x 3 25 L Velocity Directional Blue Jet Symbol 3D Part PLU29930 112 400 Size 3 D x 3 25 L Snap in SQR Jet Inserts Velocity Directional LED Jet Symbol 3D Part PLU29930 112 100 Size...

Page 45: ...ity Directional LED Jet Symbol 2D Part PLU29920 012 100 Size 2 D x 3 L Jets Flex Jet PLU23512 311 100 Duo Jet PLU23512 321 100 Precision Jet PLU2312 331 100 Pillows Cascade Pillow No Insert Black ACC0...

Page 46: ...5059 202 400 Size 3 125 x 5 L Velocity Air Control LED Symbol A Part PLU25059 202 100 Size 3 125 x 5 L Velocity Diverter Valves Velocity 2 Diverter Valve Blue Symbol D2 Part PLU25058 202 400 Size 4 5...

Page 47: ...y 1 Diverter Valve Wall Fitting LED Part PLU25030 089 200 Velocity Air Control Wall Fitting LED Part PLU25090 089 200 Velocity Diverter Valves Velocity 2 Diverter Valve Wall Fitting LED Part PLU25048...

Page 48: ...T25241 114 949 Drains Drain Super Hi Flo Suction 2 Black 640 3581LGV PLU21400146 Low Profile Drain Black 640 0511 PLU21400401 Filters Filter Cartridge Anti bacterial 75 sq ft FIL75 5D17H15FCT 3 Filter...

Page 49: ...16100335 1 to 1 port ext cord LIT16100338 Interior light with logic 7 LED LIT16100333 Interior light without logic 7 LED LIT16100337 Main light housing LED lens fitting nut LIT16100336 Replacement Cab...

Page 50: ...Lb foam Deluxe 5 3 2 0 Lb foam 84 x 84 7 foot spas Fits spa models PL 760L PL760B PPL7L PPL7B Standard Deluxe Black COV8484S53BK BK 2 COV8484D53BK BK 2 Gray COV8484S53G CC 2 COV8484D53G CC 2 Slate CO...

Page 51: ...may be trying to heat up Check if spa is in Ready or Rest mode see page 16 In cold climates if spa is not equipped with full foam or any kind of insulation it will try to maintain the set temperature...

Page 52: ...assistance Noise may be a sign of damage Contact your dealer for service Symptom Possible Solutions Spa overheats temperature greater than 110 F 43 C Overheating can occur during summer months and ma...

Page 53: ...qualified spa technician Thermal Creep Cal Spas are designed with energy efficient components and systems that are meant to sustain heat generated by the equipment which is then cycled back into the...

Page 54: ...hip or material for one year from the original date of delivery All other factory installed components not mentioned specifically including but not limited to the wood frame jets diverter valves LED l...

Page 55: ...The spa owner accepts liability for repair work performed by anyone other than the Manufacturer or a designated Cal Spa representative This Limited Warranty is void if damage occurs to the spa shell...

Page 56: ...2018 Platinum Series Spas LTR20181010 Rev H Appendix www calspas com 54...

Page 57: ...2018 Platinum Series Spas LTR20181010 Rev H Appendix www calspas com 55...

Page 58: ...2018 Platinum Series Spas LTR20181010 Rev H Appendix www calspas com 56...

Page 59: ...2018 Platinum Series Spas LTR20181010 Rev H Appendix www calspas com 57...

Page 60: ...o properly register your spa and activate coverage Write this information in the space provided below Spa Model ____________________________________________________________________________ Spa Serial...

Reviews: