background image

   

 

 

  

 

 Page 4

   

1.1  Program mode vs. Run mode 

 

CA Series products have two (2) basic modes of operation:  

a) 

Program Mode

 

 allows general configuration of the device plus IR/Serial Trigger.  

b) 

Run Mode

 

 allows IR and SERIAL triggers to be recognized and decoded.  

The device MUST BE IN PROGRAM MODE in order for it to communicate with CA-Config 
software.    

If the serial settings on the device remain at their factory settings

1

, and properly connected via a 

serial cable, the device will automatically be placed into Program mode by CA-Config software 
when  the  software  is  launched.   Program  mode  is  indicated  by  a  blinking  blue  LED  on  the 
surface of the CA device.  

If, however, the serial settings on the device have been modified, e.g., to enable remote, serial 
control of the amplifier or pre-amp, CA-Config will not be able to initiate communications with the 
device  nor  put  it  into  Program  mode.   When  this  happens,  the  device  must  be  forced  into 
Program Mode, using the following steps:  

 

Unplug power 

 

Short a 2-pin terminal block by connecting a wire that runs between pin-1 and pin-2 (hint: 
a broken paperclip works well) 

 

Insert the shorted terminal block into the 3-pin serial connector slots on the right side of 
the device 

 

Power up the device 

 

Immediately remove the shorted jumper 

 

Connect the serial cable attached to the computer running 
CA-Config software  

The unit will now be in Program mode and the top, blue LED will 
blink continually.  The LED glows a steady blue when in Run 
mode.  

  

1.2  Wiring Everything Up  

1.2.1  Power

   

All CA series units require a minimum 12VDC, 3.3A power supply, which is provided with 
the unit.   Insert the 2.5mm power supply plug into the receptacle located on the left side 
of the unit. 

                                                

 

1

 Default Settings:  BAUD=19200, PARITY=NONE, STOP=1 

 

Short to Force 

PGM Mode

 

Summary of Contents for CA-500

Page 1: ...CA 5 0 0 1 0 0 0 AUDIO AMPLIFIERS CA 1 0 5 0 PRE AMP 944 O Keefe Road Hudson WI 54016 Tel 715 381 9646 Fax 715 381 9647 www calypsocontrol com sales calypsocontrol com support calypsocontrol com...

Page 2: ...1050 OVERVIEW 3 1 1 PROGRAM MODE VS RUN MODE 4 1 2 WIRING EVERYTHING UP 4 1 3 USING CA CONFIG SOFTWARE 7 2 0 IR AND SERIAL CONTROL 11 2 1 IR COMMAND PROTOCOL 11 2 2 SERIAL COMMAND PROTOCOL 13 3 0 TECH...

Page 3: ...me compact format CA Series setup is through its on board serial programming port using its companion CA Config software utility a simple graphical interface used to configure all variable settings on...

Page 4: ...g will not be able to initiate communications with the device nor put it into Program mode When this happens the device must be forced into Program Mode using the following steps Unplug power Short a...

Page 5: ...3 will accept an unbalanced stereo or mono input via an 1 8 inch mini audio jack 1 2 6 Channel 4 Audio Input CA 1000 and CA 1050 only Channel 4 will accept a mono input via a 2 pin screw down terminal...

Page 6: ...n connector located on the right side of the unit labeled IR GND and IR1 IN Note that pin 3 is a shared ground connector 1 2 9 Headphones Headphones may be plugged into the unit using the 1 8 inch min...

Page 7: ...programming cable After launching the software select the appropriate serial port from the pull down it should automatically initiate communications with the CA unit2 Note that reselecting the serial...

Page 8: ...PA detect mute channels 1 2 and 3 and amplify channel 4 input as per most recent current channel 4 settings Note that current amplifier settings may include low volume determined by channel 4 Gain and...

Page 9: ...input levels typically but not necessarily on channel 4 the system searches only the LEFT side Hence single channel microphones must be connected to the LEFT side input or plugged into a input set to...

Page 10: ...is provided in section 2 0 of this manual which covers IR control 2 IR Trg 1st code toggle the IR receiver to process the 1st 2nd or 3rd IR code transmitted from a single IR remote control burst 3 IR...

Page 11: ...D player IR commands model CDP C715 and re encoded as 2 byte hex strings for processing efficiency All Calypso controllers with on board IR learning have the ability to automatically convert the actua...

Page 12: ...RT2 Codes User Defined When necessary you may configure the CA device to respond to ANY valid CIRT code which amounts to creating your own CIRT2 library For example the Calypso CB 1000 wall mount butt...

Page 13: ...hannel 2 3 Channel 3 4 Channel 4 Command Description ACH Return current channel selection Command Description ACF Forward to next available channel Command Description ACR Reverse to available channel...

Page 14: ...etting range 1 32 2db v 1 thru 32 Command Description AVA Return current volume setting Command Description AVMx Mute and un mute output x 0 mute 1 un mute Command Description AVM Toggle mute state Co...

Page 15: ...B 20 kHz CMRR 80 dB Protection Circuits Thermal and Short Circuit protected Yellow fault LED Output Limiter 4 settable gain levels 20db 26db 32db 36db Headphone Outputs Connector 3 5mm Stereo Jack TRS...

Page 16: ...during the warranty period that product does not conform to this warranty Calypso Control Systems shall at its sole option either repair or replace the non conforming product The warranty on the repl...

Page 17: ...SED IMPLIED STATUTORY OR OTHERWISE CALYPSO CONTROL SYSTEMS LLC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Limitation of Liability TO THE EXTEN...

Reviews: