cnRanger 800 BBU Hardware Overview
17
Removing the SFP+ Module:
Pull the bale-clasp latch with index finger towards downward
direction and gently pull the SFP+ module from the port.
Connect CPRI Fiber optic cables.
CPRI SFP+ module kits
SFP+ module kits allow connection of 2 GHz/3 GHz cnRanger RRHfrom cnRanger 800 BBU over optical
fiber cable. Use 10Gbps SFP+ module (SFP-10G-SR) to connect to 2 GHz/3 GHz cnRanger RRH. Maximum
length of optical fiber cable shall not exceed 300 meters. Use Multimode LC- LC outdoor optical fiber
cable between 2 GHz/3 GHz cnRanger RRHand cnRanger 800 BBU.
Cambium Networks CPRI fiber cable part number (N000000L131A) is recommended for use between the
2 GHz/3 GHz cnRanger RRH and junction box in order to provide optimal fit through weather proofing
gland. From junction box long length CPRI cables can be extended depending on the lengths.
Cambium does not supply long length optical fiber cables along with SFP+ module kits. Recommended
cable lengths and specifications are as shown in
Table 2 Multi-mode Optical SFP Interface per ODU
. Order
SFP module kits as shown in
Table 3 SFP module kit part numbers
from Cambium Networks.
Table 2 : Multi-mode Optical SFP Interface per ODU
Core/cladding
(microns)
Mode
Bandwidth at 850 nm
(MHz/km)
Maximum
length of optical
interface
Insertion loss
(dB)
62.5/125
Multi
160
220 m (720 ft)
2.38
62.5/125
Multi
200
275 m (900 ft)
2.6
Table 3 : SFP module kit part numbers