cnRanger 800 BBU Hardware Overview
19
Installing Sync In/Sync Out Cables on the cnRanger 800
BBU
1. Install Sync IN/Out cables for synchronizing multiple cnRanger 800 BBUs.
2. Sync OUT port of first cnRanger 800 BBU shall be connected to Sync IN port of second cnRanger
800 BBU and vice versa.
Warning
Connecting Sync OUT port of first cnRanger 800 BBU to Sync OUT of second
cnRanger 800 BBU may damage the port.
Installing a GPS antenna on the cnRanger 800 BBU
The following information describes the recommended tools and procedures to mount the GPS antenna.
Supported GPS antennas
Table 4 :Supported GPS antenna
Description
Part Number
External GPS Antenna
N000900L030A
l
Connect GPS Antenna to GPS_ANT port on the cnRanger 800 BBU.
l
Use an extension cable if longer length cable is required.
l