CAMBIUM NETWORKS
026v003
42
EPMP 2000 ACCESS POINT WITH INTELLIGENT FILTERING AND SYNC HEATER
At startup, if the ePMP 2000 Access Point with Intelligent Filtering and Sync module temperature is
at or below 32° F (0° C), an internal heater is activated to ensure that the device is able to
successfully begin operation. The unit’s heater is only activated when the unit is powered on and
will not apply heat to the device once startup is complete. When the unit temperature is greater
than 32° F (0° C), the heater is deactivated and the unit continues its startup sequence.
The effect on device startup time at various temperatures is defined in
Table 7 ePMP 2000 Access Point with Intelligent Filtering and Sync startup times based on
ambient temperature
Initial Temperature
Startup time (from power on to operational)
-22° F (-30° C)
20 minutes
-4° F (-20° C)
6 minutes
14° F (-10° C)
2 minutes, 30 seconds
EPMP 2000 ACCESS POINT WITH INTELLIGENT FILTERING AND SYNC -
EXTERNAL ANTENNA LOCATION
Find a location for the device and external antenna that meets the following requirements:
The equipment is high enough to achieve the best radio path.
People can be kept a safe distance away from the equipment when it is radiating. The safe
separation distances are defined in
Calculated distances and power compliance margins
page
The equipment is lower than the top of the supporting structure (tower, mast or building) or its
lightning air terminal.
The location is not subject to excessive wind loading. For more information, see
Access Point with Intelligent Filtering and Sync wind loading
on
Summary of Contents for ePMP
Page 198: ...CAMBIUM NETWORKS 026v003 198 Figure 61 SM Radio page Standard WiFi mode ...
Page 230: ...CAMBIUM NETWORKS 026v003 230 Figure 66 SM Network page Router mode ...
Page 466: ...CAMBIUM NETWORKS 026v003 466 ...
Page 467: ...CAMBIUM NETWORKS 026v003 467 ...
Page 468: ...CAMBIUM NETWORKS 026v003 468 Figure 87 FCC and IC certifications on 2 4 GHz product labels ...