Chapter 5: Installation
201
Mount ing bracket – PMP 4 50 Series – SM 90 0 MHz
The PMP 450i Series – SM 900 MHz has special mounting bracket option. The PMP 450i Series AP - 900
MHz mounting procedure is the same as the other 450i Series radios. The 450 Series SM 900 MHz has a
different mounting bracket which is supplied along with Yagi antenna.
Mo unt t he ODU, LPU and surg e sup p resso r
To install the ODU and top LPU, use the following procedures:
l
Attach ground cables to the ODU
l
l
l
A t t ach g r ound cab les t o t he ODU
PMP 450m Series – AP
1
Fasten an AWG 10 (or 6mm
2
) copper
ground cable to each ODU grounding
point using the M6 (small) lugs.
2
Secure the M6 grounding bolts by
applying 3 Nm torque.
Summary of Contents for PMP 450 Series
Page 92: ...Chapter 2 System hardware 92 Figure 29 MicroPoP Omni antenna implementation pattern Vertical...
Page 134: ...Chapter 3 System planning 134 Figure 51 Mast or tower installation...
Page 135: ...Chapter 3 System planning 135 Figure 52 Wall installation...
Page 136: ...Chapter 3 System planning 136 Figure 53 Roof installation...
Page 137: ...Chapter 3 System planning 137 Figure 54 GPS receiver wall installation...
Page 158: ...Chapter 3 System planning 158 Figure 61 cnMedusa Antenna...