Chapter 5: Installation
228
Figure 85 :
Grounding and lightning protection on mast or tower
Prot ect ion requirement s on a mult i- floor building
If the ODU is to be mounted on a high-rise building, it is likely that cable entry is at roof level (Roof
installation) and the equipment room is several floors below. The following additional requirements must
be observed:
l
The ODU must be below the lightning terminals and finials.
l
A grounding conductor must be installed around the roof perimeter to form the main roof
perimeter lightning protection ring.
l
Air terminals are typically installed along the length of the main roof perimeter lightning protection
ring typically every 6.1m (20ft).
l
The main roof perimeter lightning protection ring must contain at least two down conductors
connected to the grounding electrode system. The down conductors should be physically
separated from one another, as far as practical.
Figure 86 :
Grounding and lightning protection on building