Chapter 6: Compliance with safety standards
284
Band
(GHz)
Antenna
P
(W)
G
(dBi)
S
(W/ m2)
d
(m)
S
@
20
cm
(W/ m2)
5.4
Omni
0.125
9
9.39
0.08
1.99
Sector
0.050
13
9.39
0.08
1.99
5.8
Omni
0.501
9
9.69
0.17
7.92
Sector
0.199
13
9.69
0.17
7.92
Table 134 :ISED minimum safe distances – PMP/PTP 450b Retro APs 4.9 GHz, 5.1 GHz, 5.2 GHz, 5.4 GHz and
5.8 GHz
Band
(GHz)
Antenna
P
(W)
G
(dBi)
S
(W/ m2)
d
(m)
S @ 20 cm
(W/ m2)
4.9
Integrated
0.501
8
8.71
0.16
6.29
5.1
Integrated
0.501
8
9.01
0.15
6.29
5.2
Integrated
0.501
8
9.13
0.15
6.29
5.4
Integrated
0.501
8
9.39
0.15
6.29
5.8
Integrated
0.501
8
9.69
0.15
6.29
Table 135 :ISEDC minimum safe distances – PMP/PTP 450b 3.65 GHz, 4.9 GHz, 5.1 GHz, 5.2 GHz, 5.4 GHz
and 5.8 GHz
Band (GHz)
Antenna
P
(W)
G
(dBi)
S
(W/ m2)
d
(m)
S @ 20 cm
(W/ m2)
3.5
Dish
0.794
20
6.99
0.88
158.0
3.65 GHz (Lower Canada)
Dish
0.199
20
7.13
0.44
39.7
3.65 GHz (Upper Canada)
Dish
0.199
20
7.13
0.44
39.7
4.9
Dish
0.501
24
8.76
1.07
250.5
Patch Array
0.501
17
8.76
0.48
50.0
On-board
0.501
0
8.76
0.07
1.0
5.1
Dish
0.501
24
9.01
1.05
250.5
Patch Array
0.501
17
9.01
0.47
50.0
On-board
0.501
0
9.01
0.07
1.0
5.2
Dish
0.004
24
9.13
0.09
2.0
Patch Array
0.020
17
9.13
0.09
2.0
On-board
0.251
0
9.13
0.05
0.5
Summary of Contents for PMP 450 Series
Page 92: ...Chapter 2 System hardware 92 Figure 29 MicroPoP Omni antenna implementation pattern Vertical...
Page 134: ...Chapter 3 System planning 134 Figure 51 Mast or tower installation...
Page 135: ...Chapter 3 System planning 135 Figure 52 Wall installation...
Page 136: ...Chapter 3 System planning 136 Figure 53 Roof installation...
Page 137: ...Chapter 3 System planning 137 Figure 54 GPS receiver wall installation...
Page 158: ...Chapter 3 System planning 158 Figure 61 cnMedusa Antenna...